A portable micro-X-ray fluorescence spectrometer with polycapillary optics and vacuum chamber for archaeometric and other applications

被引:38
作者
Buzanich, G. [1 ]
Wobrauschek, P. [1 ]
Streli, C. [1 ]
Markowicz, A. [2 ,3 ]
Wegrzynek, D. [2 ,3 ]
Chinea-Cano, E. [2 ]
Bamford, S. [2 ]
机构
[1] TU Wien Atominst, A-1020 Vienna, Austria
[2] IAEA, Agcy Labs Seibersdorf, A-1400 Vienna, Austria
[3] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, Dept Radiometry, PL-30059 Krakow, Poland
关键词
portable micro-X-ray spectrometer; vacuum chamber; polycapillary; in situ analysis;
D O I
10.1016/j.sab.2007.08.003
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A portable focused-beam XRF spectrometer was designed, constructed, and manufactured. The spectrometer allows to detect and perform analysis of chemical elements from Na upwards. The system is equipped with a compact vacuum chamber to reduce absorption of both the excitation and the fluorescence radiation in air. A low power Pd-anode tube operated up to 50 kV and 1 mA with a point focus of 400 mu m is used as excitation source. A polycapillary lens with a spot size of about 160 pm, or a collimator with a 1 min inner diameter can be used alternatively for either focusing or collimating the primary beam. The fluorescence radiation is collected by an Si drift detector with an active area of 10 min 2 and equipped with an 8 mu m Be entrance window. A compact vacuum chamber was designed to house the X-ray beam optics and the detector snout. The chamber is attached to the X-ray tube and can be pumped down to 0.1 mbar. A Kapton(TM) window of 7.5 mu m thickness allows to locate the investigated spot at about 1-2 mm distance outside of the chamber, thus minimizing absorption losses in the excitation and X-ray fluorescence radiation paths. Two lasers pointers are mounted inside the chamber. The laser beams cross at a point outside the chamber in front of the entrance window and coincide with the focal spot of the polycapillary. This paper reports some preliminary results obtained from an in situ analysis of bronze samples as well as a comparison of these data with those given by other laboratory spectrometers and the reference values provided by the Italian bronze foundry Venturi Arte Bologna, Italy. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1252 / 1256
页数:5
相关论文
共 7 条
[1]   In situ-XAS and catalytic study of acrolein hydrogenation over silver catalyst:: Control of intramolecular selectivity by the pressure [J].
Bron, M ;
Teschner, D ;
Knop-Gericke, A ;
Scheybal, A ;
Steinhauer, B ;
Hävecker, M ;
Födisch, R ;
Hönicke, D ;
Schlögl, R ;
Claus, P .
CATALYSIS COMMUNICATIONS, 2005, 6 (05) :371-374
[2]  
GRIESSER M, 2004, COST ACT G8 WORKSH H
[3]  
*IAEA AG LAB LAB S, 2005, SITU AN BRONZ PORT X
[4]  
*IAEA AG LAB SEIB, 2001, DEV PORT XRF SPECTR
[5]  
Janssens K, 2000, X-RAY SPECTROM, V29, P73, DOI 10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO
[6]  
2-D
[7]   A portable semi-micro-X-ray fluorescence spectrometer for archaeometrical studies [J].
Zarkadas, C ;
Karydas, AG .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) :1611-1618