Maximum likelihood as a common computational framework in tomotherapy

被引:35
作者
Olivera, GH [1 ]
Shepard, DM [1 ]
Reckwerdt, PJ [1 ]
Ruchala, K [1 ]
Zachman, J [1 ]
Fitchard, EE [1 ]
Mackie, TR [1 ]
机构
[1] Univ Wisconsin, Dept Phys Med, Madison, WI 53706 USA
关键词
D O I
10.1088/0031-9155/43/11/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tomotherapy is a dose delivery technique using helical or axial intensity modulated beams. One of the strengths of the tomotherapy concept is that it can incorporate a number of processes into a single piece of equipment. These processes include treatment optimization planning, dose reconstruction and kilovoltage/megavoltage image reconstruction. A common computational technique that could be used for all of these processes would be very appealing. The maximum likelihood estimator, originally developed for emission tomography, can serve as a useful tool in imaging and radiotherapy. We believe that this approach can play an important role in the processes of optimization planning, dose reconstruction and kilovoltage and/or megavoltage image reconstruction. These processes involve computations that require comparable physical methods. They are also based on equivalent assumptions, and they have similar mathematical solutions. As a result, the maximum likelihood approach is able to provide a common framework for all three of these computational problems. We will demonstrate how maximum likelihood methods can be applied to optimization planning, dose reconstruction and megavoltage image reconstruction in tomotherapy. Results for planning optimization, dose reconstruction and megavoltage image reconstruction will be presented. Strengths and weaknesses of the methodology are analysed. Future directions for this work are also suggested.
引用
收藏
页码:3277 / 3294
页数:18
相关论文
共 52 条
[1]  
[Anonymous], 1993, E EUROPEAN CONSTITUT
[2]  
Bortfeld T, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P1
[3]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[4]   REALIZATION AND VERIFICATION OF 3-DIMENSIONAL CONFORMAL RADIOTHERAPY WITH MODULATED FIELDS [J].
BORTFELD, T ;
BOYER, AL ;
SCHLEGEL, W ;
KAHLER, DL ;
WALDRON, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (04) :899-908
[5]   SIMILARITIES AND DIFFERENCES IN RADIATION-THERAPY OPTIMIZATION AND TOMOGRAPHIC RECONSTRUCTION [J].
BRAHME, A .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (01) :6-13
[6]   OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES [J].
BRAHME, A .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) :129-140
[7]  
BRAHME A, 1994, USE COMPUTERS RAD TH, P6
[8]  
BRAHME A, 1994, PHYS MED BIOL A, V39, P498
[9]  
BRAHME A, 1995, RAD THERAPY PHYSICS, P209
[10]   DEVELOPMENTS WITH MAXIMUM-LIKELIHOOD X-RAY COMPUTED-TOMOGRAPHY [J].
BROWNE, JA ;
HOLMES, TJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :40-52