Catheter-tracking FOV MR fluoroscopy

被引:59
作者
Atalar, E
Kraitchman, DL
Carkhuff, B
Lesho, J
Ocali, O
Solaiyappan, M
Guttman, MA
Charles, HK
机构
[1] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21287 USA
[2] Johns Hopkins Appl Phys Lab, Baltimore, MD USA
[3] ISS, Singapore, Singapore
关键词
intravascular MRI; interventional MRI; catheter tracking; MR fluoroscopy;
D O I
10.1002/mrm.1910400612
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent improvements in intravascular magnetic resonance imaging techniques mandate an accurate method of monitoring the introduction of MR catheter probes into the vessel of interest. For this purpose, a novel imaging protocol and a display method have been designed, First, a roadmap 3D image data set with standard pulse sequences is obtained using an external imaging coil. Subsequently, using very narrow rectangular-FOV fast-spoiled gradient recalled (SPGR), a movie of the percutaneous placement procedure of an MR catheter probe is acquired at a rate of 7.3 frames/second. In this protocol, the probe is used to transmit RF pulses and receive MR signal. A computer program was written for image unwrapping and for displaying the unwrapped movie frames on the roadmap image. In an alternative protocol, the movie frames in two projection angles were acquired in an interleaved fashion. Frames were unwrapped and combined with a 3D roadmap and displayed on a Silicon Graphics workstation equipped with stereovision goggles. Using these methods, percutaneous catheter placement in a phantom and a dog was examined. In conclusion, a new visualization technique for MR catheter placement is proposed. Combining this technique with high resolution intravascular MRI techniques may result in a very useful diagnostic tool for the evaluation of atherosclerosis and other vessel diseases.
引用
收藏
页码:865 / 872
页数:8
相关论文
共 21 条
  • [1] High resolution intravascular MRI and MRS by using a catheter receiver coil
    Atalar, E
    Bottomley, PA
    Ocali, O
    Correia, LCL
    Kelemen, MD
    Lima, JAC
    Zerhouni, EA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 596 - 605
  • [2] ATALAR E, CATHETER TRACKING FO
  • [3] BURL M, 1996, P ISMRM 4 ANN M NEW, P403
  • [4] Intravascular magnetic resonance imaging of aortic atherosclerotic plaque composition
    Correia, LCL
    Atalar, E
    Kelemen, MD
    Ocali, O
    Hutchins, GM
    Fleg, JL
    Gerstenblith, G
    Zerhouni, EA
    Lima, JAC
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1997, 17 (12) : 3626 - 3632
  • [5] Correia Luis C. L., 1996, Journal of the American College of Cardiology, V27, p17A
  • [6] REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE
    DUMOULIN, CL
    SOUZA, SP
    DARROW, RD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) : 411 - 415
  • [7] SIMULTANEOUS DETECTION OF MULTIPLE COMPONENTS OF MOTION WITH MRI
    DUMOULIN, CL
    DARROW, RD
    EISNER, DR
    TARNAWSKI, M
    SCOTT, KT
    CARO, CG
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (04) : 652 - 660
  • [8] Gaunt W.A., 1978, Three-dimensional reconstruction in biology
  • [9] INTRAVASCULAR (CATHETER) NMR RECEIVER PROBE - PRELIMINARY DESIGN ANALYSIS AND APPLICATION TO CANINE ILIOFEMORAL IMAGING
    HURST, GC
    HUA, JM
    DUERK, JL
    COHEN, AM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 24 (02) : 343 - 357
  • [10] Kandarpa K, 1993, J Vasc Interv Radiol, V4, P419, DOI 10.1016/S1051-0443(93)71891-6