Towards absolute quantification of therapeutic monoclonal antibody in serum by LC-MS/MS using isotope-labeled antibody standard and protein cleavage isotope dilution mass spectrometry

被引:175
作者
Heudi, Olivier [1 ]
Barteau, Samuel [1 ]
Zimmer, Dieter [1 ]
Schmidt, Joerg [2 ]
Bill, Kurt [2 ]
Lehmann, Natalie [2 ]
Bauer, Christian [2 ]
Kretz, Olivier [1 ]
机构
[1] Novartis Pharma AG, DMPK Bioanalyt, CH-4002 Basel, Switzerland
[2] Novartis Pharma AG, Biotechnol Dev, CH-4002 Basel, Switzerland
关键词
D O I
10.1021/ac800205s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although LC-MS methods are increasingly used for the absolute quantification of proteins, the lack of appropriate internal standard (IS) hinders the development of rapid and standardized analytical methods for both in vitro and in vivo studies. Here, we have developed a novel method for the absolute quantification of a therapeutic protein, which is monoclonal antibody (mAb). The method combines liquid chromatography tandem mass spectrometry (LC-MS/MS) and protein cleavage isotope dilution mass spectrometry with the isotope-labeled mAb as IS. The latter was identical to the analyzed mAb with the exception that each threonine contains four C-13 atoms and one N-15 atom. Serum samples were spiked with IS prior to the overnight trypsin digestion and subsequent sample cleanup. Sample extracts were analyzed on a C-18 ACE column (150 mm x 4.6 mm) using an LC gradient time of 11 min. Endogenous mAb concentrations were determined by calculating the peak height ratio of its signature peptide to the corresponding isotope-labeled peptide. The linear dynamic range was established between 5.00 and 1000 mu g/mL mAb with accuracy and precision within +/- 15% at all concentrations and below +/- 20% at the LLOQ (lower limit of quantification). The overall method recovery in terms of mAb was 14%. The losses due to sample preparation (digestion and purification) were 72% from which about 32% was due to the first step of the method, the sample digestion. This huge loss during sample preparation strongly emphasizes the necessity to employ an IS right from the beginning. Our method was successfully applied to the mAb quantification in marmoset serum study samples, and the precision obtained on duplicate samples was, in most cases, below 20%. The comparison with enzyme-linked immunosorbent assay (ELISA) showed higher exposure in terms of AUC and C-max with the LC-MS/MS method. Possible reasons for this discrepancy are discussed in this study. The results of this study indicate that our LC-MS/MS method is a simple, rapid, and precise approach for the therapeutic mAb quantification to support preclinical and clinical studies.
引用
收藏
页码:4200 / 4207
页数:8
相关论文
共 24 条
[1]   Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins [J].
Anderson, L ;
Hunter, CL .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (04) :573-588
[2]   Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-MS/MS using protein cleavage and isotope dilution mass spectrometry [J].
Barnidge, DR ;
Goodmanson, MK ;
Klee, GG ;
Muddiman, DC .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (03) :644-652
[3]  
Barr JR, 1996, CLIN CHEM, V42, P1676
[4]   Detection of functional ricin by immunoaffinity and liquid chromatography-tandem mass spectrometry [J].
Becher, F. ;
Duriez, E. ;
Volland, H. ;
Tabet, J. C. ;
Ezan, E. .
ANALYTICAL CHEMISTRY, 2007, 79 (02) :659-665
[5]   Quantification of small therapeutic proteins in plasma by liquid chromatography - Tandem mass spectrometry: Application to an elastase inhibitor EPI-hNE4 [J].
Becher, F ;
Pruvost, A ;
Clement, G ;
Tabet, JC ;
Ezan, E .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2306-2313
[6]   Multiplexed absolute quantification in proteomics using artificial QCAT proteins of concatenated signature peptides [J].
Beynon, RJ ;
Doherty, MK ;
Pratt, JM ;
Gaskell, SJ .
NATURE METHODS, 2005, 2 (08) :587-589
[7]   Isotope-labeled protein standards [J].
Brun, Virginie ;
Dupuis, Alain ;
Adrait, Annie ;
Marcellin, Marlene ;
Thomas, Damien ;
Court, Magali ;
Vandenesch, Francois ;
Garin, Jerome .
MOLECULAR & CELLULAR PROTEOMICS, 2007, 6 (12) :2139-2149
[8]   Proteomic analysis of human serum by two-dimensional differential gel electrophoresis after depletion of high-abundant proteins [J].
Chromy, BA ;
Gonzales, AD ;
Perkins, J ;
Choi, MW ;
Corzett, MH ;
Chang, BC ;
Corzett, CH ;
McCutchen-Maloney, SL .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (06) :1120-1127
[9]   Absolute quantitation of β-lactoglobulin by protein liquid chromatography -: Mass spectrometry and its application to different milk products [J].
Czerwenka, Christoph ;
Maier, Irene ;
Potocnik, Natascha ;
Pittner, Fritz ;
Lindner, Wolfgang .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5165-5172
[10]   Recommendations for the bioanalytical method validation of ligand-binding assays to support pharmacokinetic assessments of macromolecules [J].
DeSilva, B ;
Smith, W ;
Weiner, R ;
Kelley, M ;
Smolec, JM ;
Lee, B ;
Khan, M ;
Tacey, R ;
Hill, H ;
Celniker, A .
PHARMACEUTICAL RESEARCH, 2003, 20 (11) :1885-1900