Analysis of a drift tube at ambient pressure: Models and precise measurements in ion mobility spectrometry

被引:58
作者
Eiceman, GA [1 ]
Nazarov, EG
Rodriguez, JE
Stone, JA
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
[2] Queens Univ, Dept Chem, Kingston, ON K7L 3N6, Canada
关键词
D O I
10.1063/1.1392339
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Mobility spectra for positive ions, created from a Ni-63 foil in purified air at ambient pressure (660 Torr) with 0.15 ppm moisture, were obtained with a drift tube with a discrete drift ring design at 250 degreesC as electric fields for components were individually and independently varied. Peak area, peak width, baseline intensity, drift times, and reduced mobilities (K-o) were used to measure the function and performance of each component and findings were interpreted using a model for the transport of thermalized ions in weak electric fields at ambient pressure. Transit times and intensities for ions in drift tubes at ambient pressure can be understood through a detailed knowledge of the fields local to a component and derivations from theory of ion transport. Prolonged ion residence in the drift region resulted in ion transformations even for highly purified gases of low moisture at high temperature. These findings suggest that mobility spectra may be obtained with uniformly high quality and reproducibility only under conditions when ion residence time is the primary point of reference in obtaining spectra. Other regions of the drift tube were optimized and newly observed chemistry occurred in the aperture to detector region. The sampling of ions by such an ion shutter was found to inherently bias the ion distributions and alter actual lengths of drift regions. Consequently, drift lengths measured from physical configurations of drift tubes will be inadequate for precise measurements of drift times. These studies establish baseline measurements for evaluating drift tubes that should be generally applicable for optimizing performance in other drift tubes with discrete drift ring designs. Also, these results demonstrate that precise measurements in ion mobility spectrometry (IMS) will require attention to detail not heretofore carefully regarded in modern analytical IMS. (C) 2001 American Institute of Physics.
引用
收藏
页码:3610 / 3621
页数:12
相关论文
共 43 条
[1]  
ALBRITTEN DL, 1967, THESIS GEORGIA I TEC
[2]   HALOGENATED COMPOUND RESPONSE IN AN OXYGEN DOPED ION MOBILITY DETECTOR FOR CAPILLARY GAS-CHROMATOGRAPHY [J].
BAIM, MA ;
HILL, HH .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (01) :4-10
[3]   TUNABLE SELECTIVE DETECTION FOR CAPILLARY GAS-CHROMATOGRAPHY BY ION MOBILITY MONITORING [J].
BAIM, MA ;
HILL, HH .
ANALYTICAL CHEMISTRY, 1982, 54 (01) :38-43
[4]   Classification of ion mobility spectra by functional groups using neural networks [J].
Bell, S ;
Nazarov, E ;
Wang, YF ;
Eiceman, GA .
ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) :121-133
[5]   Neural network recognition of chemical class information in mobility spectra obtained at high temperatures. [J].
Bell, S ;
Nazarov, E ;
Wang, YF ;
Rodriguez, JE ;
Eiceman, GA .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1192-1198
[6]   USING NONLINEAR FIELDS IN HIGH-PRESSURE SPECTROMETRY [J].
BLANCHARD, WC .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 95 (02) :199-210
[7]  
CARR TW, 1978, SURFACE CONTAMINATIO, P819
[8]   SURFACE-INDUCED ION NEUTRALIZATION WITH HIGH-ENERGY DEPOSITION [J].
CHORUSH, RA ;
VIDAVSKY, I ;
MCLAFFERTY, FW .
ORGANIC MASS SPECTROMETRY, 1993, 28 (10) :1016-1020
[9]   PLASMA CHROMATOGRAPHY - A NEW DIMENSION FOR GAS CHROMATOGRAPHY AND MASS SPECTROMETRY [J].
COHEN, MJ ;
KARASEK, FW .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1970, 8 (06) :330-&
[10]   KINETIC STUDY OF PROTON HYDRATE H+ (H2O)N EQUILIBRIA IN GAS-PHASE [J].
CUNNINGHAM, AJ ;
PAYZANT, JD ;
KEBARLE, P .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1972, 94 (22) :7627-+