Determination of cadmium and lead in table salt by sequential multi-element flame atomic absorption spectrometry

被引:88
作者
Amorim, FAC [1 ]
Ferreira, SLC [1 ]
机构
[1] Univ Fed Bahia, Inst Qum Nucl Excelencia Quim Anal Bahia, Grp Pesquisa Quim Anal, BR-40170290 Salvador, BA, Brazil
关键词
cadmium; lead; table salt samples;
D O I
10.1016/j.talanta.2004.08.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present paper, a simultaneous pre-concentration procedure for the sequential determination of cadmium and lead in table salt samples using flame atomic absorption spectrometry is proposed. This method is based on the liquid-liquid extraction of cadmium(II) and lead(II) ions as dithizone complexes and direct aspiration of the organic phase for the spectrometer. The sequential determination of cadmium and lead is possible using a computer program. The optimization step was performed by a two-level fractional factorial design involving the variables: pH, dithizone mass, shaking time after addition of dithizone and shaking time after addition of solvent. In the studied levels these variables are not significant. The experimental conditions established propose a sample volume of 250 mL and the extraction process using 4.0 mL of methyl isobutyl ketone. This way, the procedure allows determination of cadmium and lead in table salt samples with a pre-concentration factor higher than 80, and detection limits of 0.3 ng g(-1) for cadmium and 4.2 ng g(-1) for lead. The precision expressed as relative standard respectively, and of 3.2 and 1.1 % for lead concentration deviation (n = 10) were 5.6 and 2.6% for cadmium concentration of 2 and 20 ng(-1), of 20 and 200 ng g(-1), respectively. Recoveries of cadmium and lead in several samples, measured by standard addition technique, proved also that this procedure is not affected by the matrix and can be applied satisfactorily for the determination of cadmium and lead in saline samples. The method was applied for the evaluation of the concentration of cadmium and lead in table salt samples consumed in Salvador City, Bahia, Brazil. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:960 / 964
页数:5
相关论文
共 37 条
[1]   SIMULTANEOUS DETERMINATION OF 7 TRACE-METALS IN POTABLE WATER USING A VIDICON ATOMIC-ABSORPTION SPECTROMETER [J].
ALDOUS, KM ;
MITCHELL, DG ;
JACKSON, KW .
ANALYTICAL CHEMISTRY, 1975, 47 (07) :1034-1037
[2]   A liquid-liquid microextraction system for Pb and Cd enrichment and determination by flame atomic absorption spectrometry. [J].
Carasek, E ;
Tonjes, JW ;
Scharf, M .
QUIMICA NOVA, 2002, 25 (05) :748-752
[3]   A new method of microvolume back-extraction procedure for enrichment of Pb and Cd and determination by flame atomic absorption spectrometry [J].
Carasek, E ;
Tonjes, JW ;
Scharf, M .
TALANTA, 2002, 56 (01) :185-191
[4]   Separation and pre-concentration of cadmium, copper, lead, nickel and zinc by solid-liquid extraction of their cocrystallized naphthalene dithizone chelate in saline matrices [J].
Costa, ACS ;
Lopes, L ;
Korn, MDA ;
Portela, JG .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2002, 13 (05) :674-678
[5]   DETERMINATION OF CADMIUM AND LEAD IN BLOOD REFERENCE SAMPLES BY SIMULTANEOUS GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
DEVAL, A ;
SNEDDON, J .
MICROCHEMICAL JOURNAL, 1995, 52 (01) :96-100
[6]   A sensitive spectrophotometric method for lead determination by flow injection analysis with on-line preconcentration [J].
Di Nezio, MS ;
Palomeque, ME ;
Band, BSF .
TALANTA, 2004, 63 (02) :405-409
[7]   Multivariate optimization and validation studies in on-line pre-concentration system for lead determination in drinking water and saline waste from oil refinery [J].
dos Santos, WL ;
dos Santos, CMM ;
Costa, JLO ;
Andrade, HMC ;
Ferreira, SLC .
MICROCHEMICAL JOURNAL, 2004, 77 (02) :123-129
[8]   Application of three-variables Doehlert matrix for optimisation of an on-line pre-concentration system for zinc determination in natural water samples by flame atomic absorption spectrometry [J].
dos Santos, WNL ;
Santos, CMC ;
Ferreira, SLC .
MICROCHEMICAL JOURNAL, 2003, 75 (03) :211-221
[9]   OPTIMIZATION OF A SIMULTANEOUS MULTIELEMENT ATOMIC-ABSORPTION SPECTROMETER [J].
FARAH, KS ;
SNEDDON, J .
TALANTA, 1993, 40 (06) :879-882
[10]  
FARAH KS, 1993, ANAL LETT, V26, P709