Follow-up of intracranial aneurysms treated with detachable coils: Comparison of gadolinium-enhanced 3D time-of-flight MR angiography and digital subtraction angiography

被引:84
作者
Boulin, A [1 ]
Pierot, L [1 ]
机构
[1] Hop Foch, Dept Diagnost & Therapeut Neuroradiol, F-92151 Suresnes, France
关键词
aneurysm; intracranial; rupture; therapy; angiography; comparative studies; interventional procedures;
D O I
10.1148/radiology.219.1.r01mr06108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare three-dimensional (3D) time-of-flight magnetic resonance (MR) angiography with digital subtraction angiography (DSA) in the follow-up of intracranial aneurysms treated with selective endovascular placement of detachable coils. MATERIALS AND METHODS: Sixty-eight consecutive patients with intracranial aneurysms were included in the prospective study. The goal was to evaluate 3D time-of-flight MR angiography versus DSA for the detection of a residual aneurysm neck or residual flow inside the coil mesh. RESULTS: Eighty-one MR angiographic and 83 DSA examinations were performed; 15 patients were examined with both modalities twice. MR angiography was not possible in two patients. In another patient, the quality of MR angiography was not sufficient to assess the treated aneurysm. In 72 of the remaining 80 MR angiographic and DSA examinations, there was good correlation between the two modalities. In 54 cases, neither image type showed remnants or recurrence, but in 18, both showed residual aneurysm. In eight cases, the MR angiographic and DSA results differed. In one of these cases, MR angiography depicted residual aneurysm but DSA depicted an arterial loop. In seven cases, a small (<3-mm) remnant was not detected at MR angiography. CONCLUSION: Because very small aneurysm remnants or recurrences probably are not clinically important, MR angiography is an option for following up intracranial aneurysms treated with detachable coils and may partly replace DSA.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 21 条
  • [1] Anzalone N, 2000, AM J NEURORADIOL, V21, P746
  • [2] Intracranial aneurysms: Detection and characterization with MR angiography with use of an advanced postprocessing technique in a blinded-reader study
    Atlas, SW
    Sheppard, L
    Goldberg, HI
    Hurst, RW
    Listerud, J
    Flamm, E
    [J]. RADIOLOGY, 1997, 203 (03) : 807 - 814
  • [3] BRADLEY WG, 1992, RADIOLOGY P, V185, P122
  • [4] Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils
    Brunereau, L
    Cottier, JP
    Sonier, CB
    Medioni, B
    Bertrand, P
    Rouleau, P
    Sirinelli, D
    Herbreteau, D
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (02) : 216 - 223
  • [5] CHUNG WC, 1992, RADIOLOGY, V185, P121
  • [6] Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils
    Cognard, C
    Weill, A
    Spelle, L
    Piotin, M
    Castaings, L
    Rey, A
    Moret, J
    [J]. RADIOLOGY, 1999, 212 (02) : 348 - 356
  • [7] Intracranial berry aneurysms: Angiographic and clinical results after endovascular treatment
    Cognard, C
    Weill, A
    Castaings, L
    Rey, A
    Moret, J
    [J]. RADIOLOGY, 1998, 206 (02) : 499 - 510
  • [8] Derdeyn CP, 1997, AM J NEURORADIOL, V18, P279
  • [9] NATURAL-HISTORY OF POSTOPERATIVE ANEURYSM RESTS
    FEUERBERG, I
    LINDQUIST, C
    LINDQVIST, M
    STEINER, L
    [J]. JOURNAL OF NEUROSURGERY, 1987, 66 (01) : 30 - 34
  • [10] Gonner F, 1998, AM J NEURORADIOL, V19, P1324