Drilling k-wires, what about the osteocytes? An experimental study in rabbits

被引:36
作者
Franssen, Bas B. G. M.
van Diest, Paul J.
Schuurman, Arnold H.
Kon, Moshe
机构
[1] Univ Med Ctr Utrecht, Dept Plast Reconstruct & Hand Surg, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Pathol, NL-3508 GA Utrecht, Netherlands
关键词
animal; Kirschner wire; drilling; histology; insertion time;
D O I
10.1007/s00402-007-0382-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction The function of osteocytes regarding osteonecrosis has been underestimated for a long time. Recently it has been suggested that apoptosis of osteocytes results in strong osteoclastic bone resorption. Death of osteocytes due to drilling may therefore increase the risk of K-wire loosening. The purposes of our in vivo study were to assess the minimal drill time needed to notice disappearance of osteocytes and to measure the distance of the empty osteocyte lacunae surrounding the drill tract in relation with the insertion time, directly and 4 weeks after drilling Kirschner (K-) wires into the femur and tibia of rabbits. Materials and methods Trocar tipped K-wires (70 mm length and 0.6 mm thickness) were drilled into the femur and tibia of 14 New Zealand white rabbits [mean body weight 2.81 kg (2.66-3.09 kg)]. Six rabbits were terminated following surgery (t = 0) and eight rabbits were terminated 4 weeks (t = 4) after surgery. Following termination, hematoxylin and eosin stained sections were cut from femur and tibia until the drill hole was visible. The sections were evaluated under a light microscope for the presence or absence of osteocytes in osteocyte lacunae surrounding the drill holes. Results All osteocyte lacunae were empty around the K-wires in 50 and 87% of the cases, directly and 4 weeks after the surgery, respectively. The osteocytes disappeared especially beyond a drilling time of 37 s (P = 0.011) and 27 s (P = 0.008) at t = 0 and t = 4, respectively. Furthermore, a significantly positive correlation was seen between the distances of the empty osteocyte lacunae surrounding the drill holes in relation with time at t = 0 (P = 0.008) and t = 4 (P = 0.000). Conclusion Although only drilling without cooling was studied, short drilling times may prevent the disappearance of osteocytes in case cooling is not used in clinical practice as is the case in percutaneous K-wire insertion.
引用
收藏
页码:83 / 87
页数:5
相关论文
共 36 条
[1]
Effect of drill speed on bone temperature [J].
Abouzgia, MB ;
Symington, JM .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 25 (05) :394-399
[2]
Abouzgia MB, 1997, INT J ORAL MAX IMPL, V12, P342
[3]
Thermal changes observed at implant sites during internal and external irrigation [J].
Benington, IC ;
Biagioni, PA ;
Briggs, J ;
Sheridan, S ;
Lamey, PJ .
CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) :293-297
[4]
Apoptotic bone cells may be engulfed by osteoclasts during alveolar bone resorption in young rats [J].
Boabaid, F ;
Cerri, PS ;
Katchburian, E .
TISSUE & CELL, 2001, 33 (04) :318-325
[5]
Brisman D L, 1996, Int J Oral Maxillofac Implants, V11, P35
[6]
Osteocyte apoptosis and osteoclast presence in chicken radii 0-4 days following osteotomy [J].
Clark, WD ;
Smith, EL ;
Linn, KA ;
Paul-Murphy, JR ;
Muir, P ;
Cook, ME .
CALCIFIED TISSUE INTERNATIONAL, 2005, 77 (05) :327-336
[7]
Cordioli G, 1997, INT J ORAL MAX IMPL, V12, P186
[8]
CORMACK DH, 1993, ESSENTIAL HIST
[9]
THERMAL-INJURY TO BONE - A VITAL-MICROSCOPIC DESCRIPTION OF HEAT-EFFECTS [J].
ERIKSSON, A ;
ALBREKTSSON, T ;
GRANE, B ;
MCQUEEN, D .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1982, 11 (02) :115-121
[10]
HEAT CAUSED BY DRILLING CORTICAL BONE - TEMPERATURE MEASURED INVIVO IN PATIENTS AND ANIMALS [J].
ERIKSSON, AR ;
ALBREKTSSON, T ;
ALBREKTSSON, B .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06) :629-631