Radiation dosage of various CT-methods in lung diagnostics

被引:3
作者
HeinzPeer, G
Weninger, F
Nowotny, R
Herold, CJ
机构
[1] LUDWIG BOLTZMANN INST RADIOL PHSY TUMORDIAGNOST,A-1090 VIENNA,AUSTRIA
[2] UNIV VIENNA,INST BIOMED TECH & PHYS,VIENNA,AUSTRIA
来源
RADIOLOGE | 1996年 / 36卷 / 06期
关键词
radiation dosage; CT methods; lung diagnostic;
D O I
10.1007/s001170050099
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction of the computed tomography index CTDI and the multiple scan average dose (MSAD) has led to standardization of the dose description in CT examinations. Despite the use of these dose parameters, many different dosages are reported in the literature for different CT methods. In addition, there is still a wide range of radiation dosimetry results reported for conventional CT, helical CT, and HRCT used in chest examinations. The variations in dosage are mainly due to differences in factors affecting the dose, i.e. beam geometry, beam quality, scanner geometry (''generation''), and operating parameters. In addition, CT dosimetry instrumentation and methodology make a contribution to dosages. Recent studies calculating differences in factors affecting dosage and CT dosimetry and using similar operating parameters, show similar results in CT dosimetry for conventional and helical CT. On the other hand, dosages for HRCT were greatly reduced. This was mainly caused by narrow beam collimation and increasing section spacing.
引用
收藏
页码:470 / 474
页数:9
相关论文
共 18 条
[1]   A COMPARISON OF RADIATION-DOSES TO THE BREAST IN COMPUTED TOMOGRAPHIC CHEST EXAMINATIONS FOR 2 SCANNING PROTOCOLS [J].
EVANS, SH ;
DAVIS, R ;
COOKE, J ;
ANDERSON, W .
CLINICAL RADIOLOGY, 1989, 40 (01) :45-46
[2]  
FAULKNER K, 1987, ACTA RADIOL, V28, P483
[3]   COMPARISON OF 2 METHODS FOR ASSESSING PATIENT DOSE FROM COMPUTED-TOMOGRAPHY [J].
GELEIJNS, J ;
VANUNNIK, JG ;
ZOETELIEF, J ;
ZWEERS, D ;
BROERSE, JJ .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (796) :360-365
[4]  
Gollnast H K, 1993, Aktuelle Radiol, V3, P20
[5]  
HEINZPEER G, 1995, RADIOLOGY, V197, P326
[6]  
JESSEN KA, 1991, SEM DOS DIAGN RAD VO
[7]   PHYSICAL PERFORMANCE-CHARACTERISTICS OF SPIRAL CT SCANNING [J].
KALENDER, WA ;
POLACIN, A .
MEDICAL PHYSICS, 1991, 18 (05) :910-915
[8]  
KRONHOLZ HL, 1979, MED PHYS, V6, P105
[9]   HIGH-RESOLUTION CT OF THE LUNGS - AN OPTIMAL APPROACH [J].
MAYO, JR ;
WEBB, WR ;
GOULD, R ;
STEIN, MG ;
BASS, I ;
GAMSU, G ;
GOLDBERG, HI .
RADIOLOGY, 1987, 163 (02) :507-510
[10]   HIGH-RESOLUTION CT OF THE CHEST - RADIATION-DOSE [J].
MAYO, JR ;
JACKSON, SA ;
MULLER, NL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :479-481