Improved performance lead iodide nuclear radiation detectors

被引:61
作者
Deich, V [1 ]
Roth, M [1 ]
机构
[1] HEBREW UNIV JERUSALEM,SCH APPL SCI,IL-91904 JERUSALEM,ISRAEL
关键词
D O I
10.1016/S0168-9002(96)00303-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Melt-grown lead iodide single crystals with an improved transport of positive charge carriers (holes) have been developed. It is shown that an energy resolution of about 3% can be obtained for gamma-radiation at 60 keV (Am-241 isotope source). Improvement of the spectrometric performance of lead iodide detectors at lower gamma-ray energies has been achieved as well due to better purification of the starting material and optimization of the etching procedure. Correlation between the detector performance and the structure of lead iodide crystals has been studied using X-ray diffraction analysis.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 15 条
  • [1] PURIFICATION, GROWTH AND POLYTYPISM OF SINGLE-CRYSTALS OF LEAD IODIDE
    CHAUDHARY, SK
    TRIGUNAYAT, GC
    [J]. JOURNAL OF CRYSTAL GROWTH, 1983, 62 (02) : 398 - 400
  • [2] INTERLAYER INTERACTION AND OPTICAL-PROPERTIES OF LAYER SEMICONDUCTORS - 2H AND 4H POLYTYPES OF PBI2
    DONI, E
    GROSSO, G
    HARBEKE, G
    MEIER, E
    TOSATTI, E
    [J]. PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 1975, 68 (02): : 569 - 574
  • [3] ATOMIC-FORCE MICROSCOPY OF LEAD IODIDE CRYSTAL-SURFACES
    GEORGE, MA
    AZOULAY, M
    JAYATIRTHA, HN
    BIAO, Y
    BURGER, A
    COLLINS, WE
    SILBERMAN, E
    [J]. JOURNAL OF CRYSTAL GROWTH, 1994, 137 (1-2) : 299 - 303
  • [4] FURTHER STUDIES OF POLYTYPISM IN LEAD IODIDE
    HANOKA, JI
    VAND, V
    [J]. JOURNAL OF APPLIED PHYSICS, 1968, 39 (11) : 5288 - &
  • [5] LEAD IODIDE NUCLEAR SPECTROMETERS
    LUND, JC
    SHAH, KS
    SQUILLANTE, MR
    SINCLAIR, F
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 89 - 92
  • [6] RECENT PROGRESS IN LEAD IODIDE X-RAY SPECTROMETER DEVELOPMENT
    LUND, JC
    SHAH, KS
    OLSCHNER, F
    ZHANG, J
    MOY, L
    MEDRICK, S
    SQUILLANTE, MR
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) : 464 - 466
  • [7] MANDELUNG O, 1983, LANDOLTBORSTEIN, V17
  • [8] PBI2 AS NUCLEAR-PARTICLE DETECTOR
    MANFREDOTTI, C
    MURRI, R
    QUIRINI, A
    VASANELLI, L
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 126 - 128
  • [9] MAYER JW, 1968, SEMICONDUCTOR DETECT, pCH5
  • [10] REASONS FOR POLYTYPISM OF CRYSTALS OF THE TYPE-MX2 .2. CLASSIFICATION OF FAULTS AND STRUCTURAL SERIES OF POLYTYPES - CONDITIONS OF POLYTYPIC GROWTH OF CDI2, PBI2, CDBR2, SNS2, SNSE2 AND TI1.2S2
    PALOSZ, B
    [J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 1983, 80 (01): : 11 - 41