Surface acoustic wave concentration of particle and bioparticle suspensions

被引:192
作者
Li, Haiyan [1 ]
Friend, James R. [1 ]
Yeo, Leslie Y. [1 ]
机构
[1] Monash Univ, Micro Nanophys Res Lab, Dept Engn Mech, Clayton, Vic 3800, Australia
关键词
surface acoustic wave; particle concentration; biosensor;
D O I
10.1007/s10544-007-9058-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A rapid particle concentration method in a sessile droplet has been developed using asymmetric surface acoustic wave (SAW) propagation on a substrate upon which the droplet is placed. Due to the asymmetry in the SAW propagation, azimuthal bulk liquid recirculation (acoustic streaming) is generated. Once the local particle concentration is sufficiently high within a particular streamline of the acoustic streaming convective flow, shear-induced migration gives rise to an inward radial force that concentrates the particles at the centre of the droplet. In this paper, a SAW device consists of a 0.75-mm thick, 127.68 degrees Y-X-axis-rotated cut, X-propagating LiNbO3 for a substrate and an interdigital transducer electrode (IDT) with 25 straight finger pairs in a simple repeating pattern, 12 mm aperture, and a wavelength of lambda=440 mu m was patterned on the substrate. The IDT was then driven with a sinusoidal signal at the resonance frequency f (0) of 8.611 MHz. To investigate the effect of particle type and size on the concentration process, three types of particles were used in this study, including fluorescent particles (1 mu m), polystyrene microspheres (3, 6, 20, 45 mu m), and living yeast cells (10-20 mu m). Different RF powers were applied ranging from 120 to 510 mW. The concentration processes occurs within 2 to 20 s, depending on the particle size, type and input radio frequency (RF) power, much faster than currently available particle concentration mechanisms due to the large convective velocities achieved using the SAW device. Moreover, this concentration method is efficient, concentrating the particles into an aggregate one-tenth the size of the original droplet. Most importantly, bioparticles can also be concentrated by this method; we have verified that yeast cells are not lysed by the SAW radiation during concentration. By using the rapid concentration process described in this work, the breadth of applications and measurement sensitivity of SAW biosensor systems should be greatly enhanced.
引用
收藏
页码:647 / 656
页数:10
相关论文
共 25 条
[1]   Real-time imaging of the surface topography of living yeast cells by atomic force microscopy [J].
Ahimou, FO ;
Touhami, A ;
Dufrêne, YF .
YEAST, 2003, 20 (01) :25-30
[2]  
BELTER PA, 1998, BIOSEPARATION DOWNST
[3]   Action of low frequency vibration on liquid droplets and particles [J].
Bennes, J. ;
Alzuaga, S. ;
Chabe, P. ;
Morain, G. ;
Cherioux, F. ;
Manceau, J.-F. ;
Bastien, F. .
ULTRASONICS, 2006, 44 :E497-E502
[4]   Sensor strategies for microorganism detection - from physical principles to imprinting procedures [J].
Dickert, FL ;
Lieberzeit, P ;
Hayden, O .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) :540-549
[5]   Flow profiling of a surface-acoustic-wave nanopump -: art. no. 056311 [J].
Guttenberg, Z ;
Rathgeber, A ;
Keller, S ;
Rädler, JO ;
Wixforth, A ;
Kostur, M ;
Schindler, M ;
Talkner, P .
PHYSICAL REVIEW E, 2004, 70 (05) :10
[6]   Ultrasonic deposition of cells on a surface [J].
Hawkes, JJ ;
Long, MJ ;
Coakley, WT ;
McDonnell, MB .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (09) :1021-1028
[7]   Fluidics - The link between micro and nano sciences and technologies [J].
Ho, CM .
14TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2001, :375-384
[8]   A comparison of protocols for the optimisation of detection of bacteria using a surface acoustic wave (SAW) biosensor [J].
Howe, E ;
Harding, G .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :641-649
[9]   Biosensors for detection of pathogenic bacteria [J].
Ivnitski, D ;
Abdel-Hamid, I ;
Atanasov, P ;
Wilkins, E .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (07) :599-624
[10]  
KONIG B, 1993, ANAL LETT, V26, P1567, DOI 10.1080/00032719308021481