Application of the slurry technique to the determination of selenium in fish samples by electrothermal atomic absorption spectrometry

被引:33
作者
Januzzi, GSB
Krug, FJ
Arruda, MAZ
机构
[1] UNIV SAO PAULO, CTR ENERGIA NUCL AGR, BR-13400970 PIRACICABA, SP, BRAZIL
[2] UNICAMP, DEPT ANALYT CHEM, CAMPINAS, SP, BRAZIL
关键词
slurry technique; selenium; electrothermal atomic absorption spectrometry; fish;
D O I
10.1039/a605308d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A slurry technique was applied in the development of a sensitive and precise method for selenium determination in fish samples without sample pre-treatment, Several pyrolysis curves were investigated and different chemical modifiers were tested. Ammonium oxalate was used to improve the selectivity. Calibration within the range 2.5-25.0 mu g l(-1) Se was performed with aqueous standards. The detection limit was calculated as 0.33 mu g l(-1) and the RSD of the measurements was 5.9% for repeatability and 9.2% for reproducibility. The reliability of the entire procedure was confirmed by analysis of a standard reference material and by comparison with a microwave digestion procedure.
引用
收藏
页码:375 / 378
页数:4
相关论文
共 31 条
[11]   DEVELOPMENT OF AN ATOMIC FLUORESCENCE SPECTROMETER FOR THE HYDRIDE-FORMING ELEMENTS [J].
CORNS, WT ;
STOCKWELL, PB ;
EBDON, L ;
HILL, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :71-77
[12]   DETERMINATION OF SELENIUM IN SELENO COMPOUNDS AND MARINE BIOLOGICAL TISSUES USING ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY [J].
DEAKER, M ;
MAHER, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (06) :423-431
[13]  
Fuller C.W., 1977, ATOM ABSORPT NEWSL, V16, P106
[14]   DETERMINATION OF SELENIUM AND TELLURIUM IN NICKEL AND NICKEL IRON-BASED ALLOYS BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY WITH A NICKEL PALLADIUM MATRIX MODIFIER [J].
GONG, BL ;
LIU, YM ;
LI, ZH ;
LIN, TZ .
ANALYTICA CHIMICA ACTA, 1995, 304 (01) :115-120
[15]   DETERMINATION OF SELENIUM IN HUMAN HAIR AND NAIL BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
HARRISON, I ;
LITTLEJOHN, D ;
FELL, GS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (03) :215-219
[16]  
HERNANDEZCORDOB.M, 1991, TALANTA, V38, P1247
[17]   ERROR ANALYSIS FOR SAMPLING OF SLURRIES - VOLUMETRIC ERRORS [J].
HOLCOMBE, JA ;
MAJIDI, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (05) :423-425
[18]   PRELIMINARY ASSESSMENT OF HOMOGENEITY OF NEW CANDIDATE AGRICULTURAL FOOD REFERENCE MATERIALS [J].
IHNAT, M ;
STOEPPLER, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (04) :455-460
[19]   DETERMINATION OF TOTAL SELENIUM CONTENT IN SEDIMENTS AND NATURAL-WATER BY GRAPHITE FURNACE-ATOMIC ABSORPTION-SPECTROSCOPY AFTER COLLECTION AS A SELENIUM(IV) COMPLEX ON ACTIVATED CARBON [J].
KUBOTA, T ;
SUZUKI, K ;
OKUTANI, T .
TALANTA, 1995, 42 (07) :949-955
[20]   DETERMINATION OF SELENIUM IN STAPLE FOODS AND TOTAL DIETS BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY WITHOUT SOLVENT-EXTRACTION [J].
KUMPULAINEN, J ;
SAARELA, KE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :165-170