Early bone tissue responses to turned and oxidized implants in the rabbit tibia

被引:51
作者
Burgos, Patricia Miranda [1 ]
Rasmusson, Lars [1 ,2 ]
Meirelles, Luiz [1 ,3 ]
Sennerby, Lars [1 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Dept Biomat, Inst Clin Sci, SE-40530 Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Dept Oral & Maxillofacial Surg, SE-40530 Gothenburg, Sweden
[3] Univ Gothenburg, Sahlgrenska Acad, Dept Prosthet Dent, Fac Odontol, SE-40530 Gothenburg, Sweden
关键词
anodic oxidation; bone formation; histology; titanium implant; turned surface;
D O I
10.1111/j.1708-8208.2007.00074.x
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Background: Previous studies have shown the formation of more bone contacts with a moderately rough and porous titanium surface, created by anodic oxidation, as compared with nonmodified turned titanium control surfaces. The mechanisms leading to a stronger bone response to oxidized titanium are not well understood. Purpose: The aim of the study was to describe the early events of bone integration of titanium implants with oxidized and turned surfaces. Materials and Methods: Nine adult New Zealand White rabbits and 18 implants were used in the study. One oxidized and one turned threaded titanium implants, which had been placed in the right tibial metaphysis, were analyzed in the present study. The implants were retrieved after 7, 14, and 28 days for light microscopic examination and histomorphometric measurements in ground sections. Results: Integration of oxidized implants was seen to occur as direct bone formation on the surface, while the integration of turned implants was a result of bone ingrowth from preexisting bone and bone marrow. For oxidized implants, an almost acellular, darkly stained layer was seen after 7 to 14 days, which later became populated with osteoblasts. The presence of osteoid seams indicated appositional bone growth from the substrate toward the surrounding tissues. The bone contact values were higher for oxidized implants, and the bone area values were higher for turned implants. Conclusions: The present study confirms the idea that implant surface modification alters the bone tissue response to titanium. The early bone formation following surgery occurs directly on the moderately rough oxidized surface, while turned titanium surfaces are integrated by the ingrowth of bone from the adjacent bone marrow and preexisting bone tissues.
引用
收藏
页码:181 / 190
页数:10
相关论文
共 26 条
[1]
Albrektsson T O, 1994, Periodontol 2000, V4, P58, DOI 10.1111/j.1600-0757.1994.tb00006.x
[2]
De novo alveolar bone formation adjacent to endosseous implants -: A model study in the dog [J].
Berglundh, T ;
Abrahamsson, I ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (03) :251-262
[3]
Brunette D.M., 2001, ENG MAT SER, P485
[4]
The effects of the surface topography of micromachined titanium substrata on cell behavior in vitro and in vivo [J].
Brunette, DM ;
Chehroudi, B .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (01) :49-57
[5]
Davies JE., 2000, BONE ENG, P1, DOI DOI 10.1061/40517(2000)138
[6]
Davies John E, 2003, J Dent Educ, V67, P932
[7]
Gotfredsen K, 2000, Clin Implant Dent Relat Res, V2, P120, DOI 10.1111/j.1708-8208.2000.tb00002.x
[8]
Hall J., 2000, APPL OSSEOINT RES, V1, P5
[9]
Ivanoff CJ, 2003, INT J ORAL MAX IMPL, V18, P341
[10]
Histologic evaluation of the bone integration of TiO2 blasted and turned titanium microimplants in humans [J].
Ivanoff, CJ ;
Hallgren, C ;
Widmark, G ;
Sennerby, L ;
Wennerberg, A .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (02) :128-134