Synthetic oligonucleotides: AFM characterisation and electroanalytical studies

被引:13
作者
Brett, AMO [1 ]
Paquim, AMC
Diculescu, V
Oretskaya, TS
机构
[1] Univ Coimbra, Fac Ciencias & Tecnol, Dept Quim, P-3004535 Coimbra, Portugal
[2] Moscow MV Lomonosov State Univ, Dept Chem, Moscow 119899, Russia
关键词
DNA; DNA biosensor; hybridisation; adsorption; non-specific adsorption; AFM;
D O I
10.1016/j.bioelechem.2004.06.008
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
One of the most important steps in designing more sensitive and stable DNA based biosensors is the immobilisation procedure of the nucleic acid probes on the transducer surface, while maintaining their conformational flexibility. MAC Mode AFM images in air demonstrated that the oligonucleotide sequences adsorb spontaneously on the electrode surface, showing the existence of pores in the adsorbed layer that reveal big parts of the electrode surface, which enables non-specific adsorption of other molecules on the uncovered areas. The electrostatic immobilisation onto a glassy carbon electrode followed by hybridisation with a complementary sequence and control with a non-complementary sequence was studied using differential pulse voltammetry and electrochemical impedance spectroscopy. Changes in the oxidation currents of guanosine and adenosine were observed after hybridisation events as well as after control experiments. Modification of the double layer capacitance that took place after hybridisation or control experiments showed that non-specific adsorption of complementary or non-complementary sequences occur allowing the formation of a mixed multilayer. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:181 / 190
页数:10
相关论文
共 26 条
[1]   PREDICTING DNA DUPLEX STABILITY FROM THE BASE SEQUENCE [J].
BRESLAUER, KJ ;
FRANK, R ;
BLOCKER, H ;
MARKY, LA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (11) :3746-3750
[2]   Atomic force microscopy of DNA immobilized onto a highly oriented pyrolytic graphite electrode surface [J].
Brett, AMO ;
Chiorcea, AM .
LANGMUIR, 2003, 19 (09) :3830-3839
[3]   Effect of pH and applied potential on the adsorption of DNA on highly oriented pyrolytic graphite electrodes. Atomic force microscopy surface characterisation [J].
Brett, AMO ;
Chiorcea, AM .
ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (02) :178-183
[4]   Atomic force microscopy characterization of an electrochemical DNA-biosensor [J].
Chiorcea, AM ;
Brett, AMO .
BIOELECTROCHEMISTRY, 2004, 63 (1-2) :229-232
[5]   Immobilization of homooligonucleotide probe layers onto Si/SiO2 substrates:: characterization by electrochemical impedance measurements and radiolabelling [J].
Cloarec, JP ;
Deligianis, N ;
Martin, JR ;
Lawrence, I ;
Souteyrand, E ;
Polychronakos, C ;
Lawrence, MF .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) :405-412
[6]   Novel hybridization indicator methylene blue for the electrochemical detection of short DNA sequences related to the hepatitis B virus [J].
Erdem, A ;
Kerman, K ;
Meric, B ;
Akarca, US ;
Ozsoz, M .
ANALYTICA CHIMICA ACTA, 2000, 422 (02) :139-149
[7]   Electrical frequency dependent characterization of DNA hybridization [J].
Gheorghe, M ;
Guiseppi-Elie, A .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (02) :95-102
[8]   Quantitative analysis for solid-phase hybridization reaction and binding reaction of DNA binder to hybrids using a quartz crystal microbalance [J].
Ito, K ;
Hashimoto, K ;
Ishimori, Y .
ANALYTICA CHIMICA ACTA, 1996, 327 (01) :29-35
[9]   Label-free electrochemical detection of DNA hybridization on gold electrode [J].
Kerman, K ;
Morita, Y ;
Takamura, Y ;
Tamiya, E .
ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (10) :887-891
[10]   Fibre-optic genosensor for specific determination of femtomolar DNA oligomers [J].
Kleinjung, F ;
Bier, FF ;
Warsinke, A ;
Scheller, FW .
ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) :51-58