Changes in sample collection and analytical techniques and effects on retrospective comparability of low-level concentrations of trace elements in ground water

被引:15
作者
Ivahnenko, T
Szabo, Z
Gibs, J
机构
[1] US Geol Survey, Trenton, NJ 08628 USA
[2] US Geol Survey, Rapid City, SD 57702 USA
关键词
ground-water sampling; trace levels; trace elements; quality assurance; baseline studies; environmental surveys;
D O I
10.1016/S0043-1354(01)00094-X
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ground-water sampling techniques were modified to reduce random low-level contamination during collection of filtered water samples for determination of trace-element concentrations. The modified sampling techniques were first used in New Jersey by the US Geological Survey in 1994 along with inductively coupled plasma-mass spectrometry (ICP-MS) analysis to determine the concentrations of 18 trace elements at the one microgram-per-liter (mug/L) level in the oxic water of the unconfined sand and gravel Kirkwood-Cohansey aquifer system, The revised technique tested included a combination of the following: collection of samples (1) with flow rates of about 2 L per minute, (2) through acid-washed single-use disposable tubing and (3) a single-use disposable 0.45-mum pore size capsule filter, (4) contained within portable glove boxes, (5) in a dedicated clean sampling van, (6) only after turbidity stabilized at values less than 2 nephelometric turbidity units (NTU), when possible. Quality-assurance data, obtained from equipment blanks and split samples, indicated that trace element concentrations, with the exception of iron, chromium, aluminum, and zinc, measured in the samples collected in 1994 were not subject to random contamination at 1 mug/L. Results from samples collected in 1994 were compared to those from samples collected in 1991 from the same 12 PVC-cased observation wells using the available sampling and analytical techniques at that time. Concentrations of copper, lead, manganese and zinc were statistically significantly lower in samples collected in 1994 than in 1991. Sampling techniques used in 1994 likely provided trace-element data that represented concentrations in the aquifer with less bias than data from 1991 when samples were collected without the same degree of attention to sample handling. Published by Elsevier Science Ltd.
引用
收藏
页码:3611 / 3624
页数:14
相关论文
共 35 条
[1]  
[Anonymous], 964165A US GEOL SURV
[2]   SAMPLING COLLOIDS AND COLLOID-ASSOCIATED CONTAMINANTS IN GROUND-WATER [J].
BACKHUS, DA ;
RYAN, JN ;
GROHER, DM ;
MACFARLANE, JK ;
GSCHWEND, PM .
GROUND WATER, 1993, 31 (03) :466-479
[3]   CLEAN TECHNIQUE MEASUREMENT OF PB, AG, AND CD IN FRESH-WATER - A REDEFINITION OF METAL POLLUTION [J].
BENOIT, G .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (11) :1987-1991
[4]   DIRECT DETECTION OF TRACE LEVELS OF URANIUM BY LASER-INDUCED KINETIC PHOSPHORIMETRY [J].
BRINA, R ;
MILLER, AG .
ANALYTICAL CHEMISTRY, 1992, 64 (13) :1413-1418
[5]   LEAD AEROSOLS IN ATMOSPHERE - INCREASING CONCENTRATIONS [J].
CHOW, TJ ;
EARL, JL .
SCIENCE, 1970, 169 (3945) :577-&
[6]  
EPA U.S, 2001, FINAL RULE, V66, P6975
[7]  
FAIRES LM, 1993, 92634 US GEOL SURV, DOI DOI 10.3133/OFR92634
[8]  
FISHMAN MJ, 1989, 5 US GEOL SURV TECHN
[9]   WELL-PURGING CRITERIA FOR SAMPLING PURGEABLE ORGANIC-COMPOUNDS [J].
GIBS, J ;
IMBRIGIOTTA, TE .
GROUND WATER, 1990, 28 (01) :68-78
[10]   Change in field turbidity and trace element concentrations during well purging [J].
Gibs, J ;
Szabo, Z ;
Ivahnenko, T ;
Wilde, FD .
GROUND WATER, 2000, 38 (04) :577-588