The application of ultra-performance liquid chromatography/tandem mass spectrometry to the detection and quantitation of apolipoproteins in human serum

被引:101
作者
Kay, Richard G. [1 ]
Gregory, Barbara [1 ]
Grace, Philip B. [1 ]
Pleasance, Steve [1 ]
机构
[1] HFL Ltd, Cambridge CB7 5WW, England
关键词
D O I
10.1002/rcm.3130
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The detection and quantitation of apolipoproteins, important markers for coronary heart disease, in serum by liquid chromatography/tandem mass spectrometry (LC/MS/MS) using multiple reaction monitoring (MRM) is reported. A tryptic digest of depleted human serum was analysed by nanoflow LC/MS/MS at a flow rate of 300 nL/min and several apolipoproteins (Apo), including Apo A1, A2, A4, C1, C2, C3, D, F and M, were successfully identified. The analysis of the same depleted serum digest by ultra-performance (UP)LC/MS/MS operating at 700 mu L/min resulted in comparable sensitivity and selectivity to the nanoflow method, but with a dramatic (similar to 20-fold) reduction in run time. The potential of UPLC/MS/MS for the rapid quantitation of proteins in biological matrices by representative tryptic peptides was further investigated using Apo Al and its corresponding stable isotopically labelled tryptic AQUA peptide (DYVSQFEGSALGK). A set of serum-based Apo Al calibrators from a clinical analyser kit were digested without depletion following the addition of the AQUA peptide and analysed using UPLC/MS/MS. A linear calibration curve was generated from peak area ratios to the labelled peptide with a coefficient of correlation of 0.9989. Standard curves were also generated for other apolipoproteins together with Apo B100, Apo E, lecithin cholesterol acyltransferase and albumin, which were also detected in the standards. The concentration of Apo Al in five fresh undepleted human serum samples and a quality control (QC) sample were determined using both the UPLC/MS/MS method and a clinical analyser. Results were comparable and the quantitative study, involving 80 injections which took hours rather than days to complete, demonstrates the high-throughput potential of UPLC/MS/MS to quantify multiple serum proteins without the need for antibodies, and thus provide an alternative to the use of clinical analysers for serum protein biomarkers. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:2585 / 2593
页数:9
相关论文
共 15 条
[1]   Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins [J].
Anderson, L ;
Hunter, CL .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (04) :573-588
[2]  
Barr JR, 1996, CLIN CHEM, V42, P1676
[3]   Lipoproteomics II: Mapping of proteins in high-density lipoprotein using two-dimensional gel electrophoresis and mass spectrometry [J].
Karlsson, H ;
Leanderson, P ;
Tagesson, C ;
Lindahl, M .
PROTEOMICS, 2005, 5 (05) :1431-1445
[4]   Lipoproteomics I: Mapping of proteins in low-density lipoprotein using two-dimensional gel electrophoresis and mass spectrometry [J].
Karlsson, H ;
Leanderson, P ;
Tagesson, C ;
Lindahl, M .
PROTEOMICS, 2005, 5 (02) :551-565
[5]  
KAY RG, 2006, INT MASS SPECTR C PO, P224
[6]  
KIRSCH S, 2007, IN PRESS J CHROMATOG
[7]   Quantification of C-reactive protein in the serum of patients with rheumatoid arthritis using multiple reaction monitoring mass spectrometry and 13C-labeled peptide standards [J].
Kuhn, E ;
Wu, J ;
Karl, J ;
Liao, H ;
Zolg, W ;
Guild, B .
PROTEOMICS, 2004, 4 (04) :1175-1186
[8]   Comparison of ultra-performance liquid chromatography and high-performance liquid chromatography for the determination of priority pesticides in baby foods by tandem quadrupole mass spectrometry [J].
Leandro, CC ;
Hancock, P ;
Fussell, RJ ;
Keely, BJ .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (01) :94-101
[9]   Quantification of intermediate-abundance proteins in serum by multiple reaction monitoring mass spectrometry in a single-quadrupole ion trap [J].
Lin, Shanhua ;
Shaler, Thomas A. ;
Becker, Christopher H. .
ANALYTICAL CHEMISTRY, 2006, 78 (16) :5762-5767
[10]   SERUM A1-APOLIPOPROTEIN AND B-APOLIPOPROTEIN DETERMINATION - COMPARISON OF AN IMMUNOTURBIDIMETRIC METHOD WITH A MONOCLONAL-ANTIBODY-BASED RADIAL IMMUNODIFFUSION ASSAY [J].
POSTIGLIONE, L ;
SPANO, A ;
VARRICCHIO, P ;
LARIZZA, G ;
ORIENTE, A ;
GATTOZZI, D ;
ORIENTE, P .
INTERNATIONAL JOURNAL OF CLINICAL & LABORATORY RESEARCH, 1992, 21 (04) :318-320