Changes in the three-dimensional microstructure of human tibial cancellous bone in early osteoarthritis

被引:158
作者
Ding, M [1 ]
Odgaard, A [1 ]
Hvid, I [1 ]
机构
[1] Aarhus Univ Hosp, Orthopaed Res Lab, DK-8000 Aarhus C, Denmark
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2003年 / 85B卷 / 06期
关键词
D O I
10.1302/0301-620X.85B6.12595
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We obtained medial and lateral subchondral cancellous bone specimens from ten human postmortem proximal tibiae with early osteoarthritis (OA) and ten normal age- and gender-matched proximal tibiae. The specimens were scanned by micro-CT and the three-dimensional microstructural properties were quantified. Medial OA cancellous bone was significantly thicker and markedly plate-like, but lower in mechanical properties than normal bone. Similar microstructural changes were also observed for the lateral specimens from OA bone, although there had been no sign of cartilage damage. The increased trabecular thickness and density, but relatively decreased connectivity suggest a mechanism of bone remodelling in early OA as a process of filling trabecular cavities. This process leads to a progressive change of trabeculae from rod-like to plate-like, the opposite to that of normal ageing. The decreased mechanical properties of subchondral cancellous bone in OA, which are due to deterioration in architecture and density, indicate poor bone quality.
引用
收藏
页码:906 / 912
页数:7
相关论文
共 34 条
[1]
Bailey AJ, 1997, GERONTOLOGY, V43, P296
[2]
Fractal signature analysis measures cancellous bone organisation in macroradiographs of patients with knee osteoarthritis [J].
BucklandWright, JC ;
Lynch, JA ;
Macfarlane, DG .
ANNALS OF THE RHEUMATIC DISEASES, 1996, 55 (10) :749-755
[3]
Burr DB, 1997, MICROSC RES TECHNIQ, V37, P343, DOI 10.1002/(SICI)1097-0029(19970515)37:4<343::AID-JEMT9>3.0.CO
[4]
2-L
[5]
EVALUATION OF ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF HUMAN TRABECULAR BONE FROM THE MAJOR METAPHYSEAL REGIONS WITH MATERIALS TESTING AND COMPUTED-TOMOGRAPHY [J].
CIARELLI, MJ ;
GOLDSTEIN, SA ;
KUHN, JL ;
CODY, DD ;
BROWN, MB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :674-682
[6]
Dequeker J, 1997, J RHEUMATOL, V24, P795
[7]
Age variations in the properties of human tibial trabecular bone [J].
Ding, M ;
Dalstra, M ;
Danielsen, CC ;
Kabel, J ;
Hvid, I ;
Linde, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06) :995-1002
[8]
Accuracy of cancellous bone volume fraction measured by micro-CT scanning [J].
Ding, M ;
Odgaard, A ;
Hvid, I .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :323-326
[9]
Age-related variations in the microstructure of human tibial cancellous bone [J].
Ding, M ;
Odgaard, A ;
Linde, F ;
Hvid, I .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (03) :615-621
[10]
Quantification of age-related changes in the structure model type and trabecular thickness of human tibial cancellous bone [J].
Ding, M ;
Hvid, I .
BONE, 2000, 26 (03) :291-295