Beware: The misuse of technology and the law of unintended consequences

被引:22
作者
Freeman, John M. [1 ]
机构
[1] Johns Hopkins Med Inst, Berman Inst Bioeth, Dept Neurol & Pediat, Profess Neurol & Pediat, Baltimore, MD USA
关键词
ethics of study design; fetal heart rate monitoring; aEEG; automated EEG;
D O I
10.1016/j.nurt.2007.04.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Electronic monitoring of the fetal heart rate during labor (EFM), originally designed to assess fetal stress and allow the early detection of the compromised fetus, has instead led to increasing maternal morbidity without decreasing fetal morbidity. The unintended consequences of this technologic advance have led to the creation of a pseudodisease and unwarranted intervention in response to its detection. Is it ethical to introduce a new technology without adequate assessment of its possible consequences? Are we about to repeat this (error resulting from the introduction of EFM?) There is increasing interest in monitoring the function of the newborn brain, to enable the early detection of subclinical seizures. The monitor may also be used for assessing brain function in older children and adults who are comatose or paralyzed and cannot appropriately respond to stimuli. Use of this amplitude-integrated electroencephalography (aEEG) in the newborn for detection of seizures and other brain abnormalities is not dissimilar to the use of electronic fetal heart rate monitoring. Whether seizures or subclinical seizures themselves cause harm to the developing nervous system is unclear. The effectiveness of medications for treatment of seizures in the newborn has not been established. Therefore, the consequences of introducing automated EEG for the detection of subclinical neonatal seizures are likely to be similar to the results of the introduction of EFM: creation of another pseudodisease, followed by unwarranted intervention, and increased legal liability. What are the ethics of continued approval and introduction of unevaluated technology? What is the wisdom of its use? Beware of the unintended consequences.
引用
收藏
页码:549 / 554
页数:6
相关论文
共 23 条
[1]   Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour [J].
Alfirevic, Z. ;
Devane, D. ;
Gyte, G. M. L. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2006, (03)
[2]  
Avoli Massimo, 2006, Epilepsy Curr, V6, P203, DOI 10.1111/j.1535-7511.2006.00146.x
[3]   Newborn screening technology: Proceed with caution [J].
Botkin, JR ;
Clayton, EW ;
Fost, NC ;
Burke, W ;
Murray, TH ;
Baily, MA ;
Wilfond, B ;
Berg, A ;
Ross, LF .
PEDIATRICS, 2006, 117 (05) :1793-1799
[4]   Summary proceedings from the neurology group on neonatal seizures [J].
Clancy, RR .
PEDIATRICS, 2006, 117 (03) :S23-S27
[5]   Avoiding the unintended consequences of growth in medical care - How might more be worse? [J].
Fisher, ES ;
Welch, HG .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (05) :446-453
[6]   NO-FAULT CEREBRAL-PALSY INSURANCE - AN ALTERNATIVE TO THE OBSTETRICAL MALPRACTICE LOTTERY [J].
FREEMAN, AD ;
FREEMAN, JM .
JOURNAL OF HEALTH POLITICS POLICY AND LAW, 1989, 14 (04) :707-718
[7]   The use of amplitude-integrated electroencephalography: Beware of its unintended consequences [J].
Freeman, John M. .
PEDIATRICS, 2007, 119 (03) :615-617
[8]   Ethics and evidence in clinical trials [J].
Goodman, SN .
CLINICAL TRIALS, 2005, 2 (03) :195-196
[9]   Intrapartum electronic fetal heart rate monitoring and the prevention of perinatal brain injury [J].
Graham, Ernest M. ;
Petersen, Scott M. ;
Christo, Dana K. ;
Fox, Harold E. .
OBSTETRICS AND GYNECOLOGY, 2006, 108 (03) :656-666
[10]   Cost-effectiveness analyses alongside randomised clinical trials [J].
Gray, Alastair M. .
CLINICAL TRIALS, 2006, 3 (06) :538-542