Quantifying serum antiplague antibody with a fiber-optic biosensor

被引:26
作者
Anderson, GP
King, KD
Cao, LK
Jacoby, M
Ligler, FS
Ezzell, J
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
[2] USA, Med Res Inst Infect Dis, Appl Res Div, Ft Detrick, MD 21702 USA
[3] Geocenters Inc, Ft Washington, MD 20744 USA
关键词
D O I
10.1128/CDLI.5.5.609-612.1998
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The fiber-optic biosensor, originally developed to detect hazardous biological agents such as protein toxins or bacterial cells, has been utilized to quantify the concentration of serum antiplague antibodies. This biosensor has been used to detect and quantify the plague fraction I antigen in serum, plasma, and whole-blood samples, but its ability to quantify serum antibodies has not been demonstrated. By using a competitive assay, the concentration of serum antiplague antibodies was ascertained in the range of 2 to 15 mu g/ml. By making simple dilutions, concentrations for 11 serum samples whose antiplague antibody concentrations were unknown were determined and were found to be in good agreement with enzyme-linked immunosorbent assay results. The competitive assay method could be used to effectively determine the exposure to plague of animals or humans or could be applied to other diseases, such as hepatitis or AIDS, where the presence of antibodies is used to diagnose infection.
引用
收藏
页码:609 / 612
页数:4
相关论文
共 20 条
[1]  
AMANTE L, 1972, Journal of Immunological Methods, V1, P289, DOI 10.1016/0022-1759(72)90006-3
[2]   A FIBER OPTIC BIOSENSOR - COMBINATION TAPERED FIBERS DESIGNED FOR IMPROVED SIGNAL ACQUISITION [J].
ANDERSON, GP ;
GOLDEN, JP ;
LIGLER, FS .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) :249-256
[3]  
BAKER EE, 1952, J IMMUNOL, V68, P131
[4]   USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES [J].
BHATIA, SK ;
SHRIVERLAKE, LC ;
PRIOR, KJ ;
GEORGER, JH ;
CALVERT, JM ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :408-413
[5]  
Butler T., 1983, Plague and Other Yersinia Infections
[6]   DETECTION OF YERSINIA-PESTIS FRACTION-1 ANTIGEN WITH A FIBER OPTIC BIOSENSOR [J].
CAO, LK ;
ANDERSON, GP ;
LIGLER, FS ;
EZZELL, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (02) :336-341
[7]  
CARVALHO LB, 1996, SENSOR ACTUAT B-CHEM, V35, P427
[8]   SEROLOGICAL SURVEILLANCE OF PLAGUE IN DOGS AND CATS, CALIFORNIA, 1979-1991 [J].
CHOMEL, BB ;
JAY, MT ;
SMITH, CR ;
KASS, PH ;
RYAN, CP ;
BARRETT, LR .
COMPARATIVE IMMUNOLOGY MICROBIOLOGY AND INFECTIOUS DISEASES, 1994, 17 (02) :111-123
[9]  
EIGLER FS, 1991, Patent No. 5077210
[10]   PLAGUE (YERSINIA-PESTIS) IN CATS - DESCRIPTION OF EXPERIMENTALLY INDUCED DISEASE [J].
GASPER, PW ;
BARNES, AM ;
QUAN, TJ ;
BENZIGER, JP ;
CARTER, LG ;
BEARD, ML ;
MAUPIN, GO .
JOURNAL OF MEDICAL ENTOMOLOGY, 1993, 30 (01) :20-26