Prussian-Blue-based amperometric biosensors in flow-injection analysis

被引:172
作者
Karyakin, AA
Karyakina, EE
Gorton, L
机构
[1] LUND UNIV, DEPT ANALYT CHEM, S-22100 LUND, SWEDEN
[2] MOSCOW MV LOMONOSOV STATE UNIV, DEPT CHEM, MOSCOW 119899, RUSSIA
关键词
alcohol oxidase; amperometric biosensor; flow injection; glucose oxidase; Prussian Blue;
D O I
10.1016/0039-9140(96)01909-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Optimisation of the electrodeposition of Prussian Blue onto mirrored glassy carbon electrodes yielded a modified electrode practically insensitive to oxygen reduction. At the same time the electrode activity towards hydrogen peroxide reduction was extremely high. This allowed the detection of hydrogen peroxide by electroreduction over a wide potential range. Flow-injection investigations of this electrode inserted into a flowthrough electrochemical cell of the confined wall-jet type showed that the response for hydrogen peroxide is limited by diffusion. Glucose and alcohol biosensors were made by immobilisation of glucose oxidase and alcohol oxidase respectively, within a Nafion layer, onto the top of the Prussian-Blue-modified electrodes. By increasing the density of Nafion and decreasing the measuring potential the glucose biosensor was made completely insensitive to both ascorbate and acetominophes.
引用
收藏
页码:1597 / 1606
页数:10
相关论文
共 22 条
  • [1] ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE
    APPELQVIST, R
    MARKOVARGA, G
    GORTON, L
    TORSTENSSON, A
    JOHANSSON, G
    [J]. ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) : 237 - 247
  • [2] Bard A.J, 1980, Electrochemical methods: Fundamentals and applications
  • [3] BARTLETT P N, 1991, Progress in Reaction Kinetics, V16, P55
  • [4] BEREZIN IV, 1978, DOKL AKAD NAUK SSSR+, V240, P615
  • [5] AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION
    CHI, QJ
    DONG, SJ
    [J]. ANALYTICA CHIMICA ACTA, 1995, 310 (03) : 429 - 436
  • [6] STABILIZATION OF ANALYTICAL ENZYMES USING A NOVEL POLYMER CARBOHYDRATE SYSTEM AND THE PRODUCTION OF A STABILIZED, SINGLE REAGENT FOR ALCOHOL ANALYSIS
    GIBSON, TD
    HIGGINS, IJ
    WOODWARD, JR
    [J]. ANALYST, 1992, 117 (08) : 1293 - 1297
  • [7] CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS
    GORTON, L
    [J]. ELECTROANALYSIS, 1995, 7 (01) : 23 - 45
  • [8] SELECTIVE DETECTION IN FLOW-ANALYSIS BASED ON THE COMBINATION OF IMMOBILIZED ENZYMES AND CHEMICALLY MODIFIED ELECTRODES
    GORTON, L
    CSOREGI, E
    DOMINGUEZ, E
    EMNEUS, J
    JONSSONPETTERSSON, G
    MARKOVARGA, G
    PERSSON, B
    [J]. ANALYTICA CHIMICA ACTA, 1991, 250 (01) : 203 - 248
  • [9] ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    GUILBAULT, GG
    LUBRANO, GJ
    [J]. ANALYTICA CHIMICA ACTA, 1973, 64 (03) : 439 - 455
  • [10] WALL-JET ELECTRODE IN CONTINUOUS MONITORING VOLTAMMETRY
    GUNASINGHAM, H
    FLEET, B
    [J]. ANALYTICAL CHEMISTRY, 1983, 55 (08) : 1409 - 1414