Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: A comparison among LiDCO, transesophageal echochardiography, and pulmonary artery catheter

被引:47
作者
Belloni, Luigi [1 ,2 ]
Pisano, Antonio [3 ]
Natale, Armando [1 ,2 ]
Piccirillo, Maria Rosario [1 ,2 ]
Piazza, Luigi [1 ,2 ]
Ismeno, Gennaro [1 ,2 ]
De Martino, Giovanni [3 ]
机构
[1] Sant Anna & San Sebastiano Hosp, Dept Cardiac Anaesthesia, Caserta, Italy
[2] Sant Anna & San Sebastiano Hosp, ICU, Caserta, Italy
[3] Univ Naples Federico 2, Sch Anaesthesia & Intens Care, Naples, Italy
关键词
cardiovascular monitoring; cardiovascular physiology/pharmacology; fluid therapy; transesophageal echocardiography; off-pump coronary artery bypass surgery;
D O I
10.1053/j.jvca.2007.07.007
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To verify the reliability of different markers of fluid-responsiveness during off-pump cardiac surgery (OPCAB). Design: A clinical prospective, nonblinded, nonrandomized study. Setting: A community hospital. Participants: Nineteen patients. Interventions: Pulmonary artery catheter (PAC), LiDCO (LiDCO, London, UK), and transesophageal echocardiography (TEE) parameters were measured before (W) and after (t1) a fluid challenge was performed 20 minutes after induction of anesthesia, but before sternotomy and without inotropic infusion. A Student t test and Spearman test were performed for statistical analysis. Measurements and Main Results: According to the variation of cardiac index after the fluid challenge (Delta CI%), 2 groups of patients were identified: the responders (Re, Delta CI% > 15%) and the nonresponders (nRe). Mean pulse pressure variation (PPV) and mean stroke volume variation (SVV) before the fluid challenge (t0) were significantly different between the 2 groups. No significant differences were shown in systolic pressure variation (SPV), left ventricular end-diastolic area, left ventricular end-diastolic volume, and peak changes of aortic flow (Delta VAo). A statistically significant correlation was observed between ACI% and PPV (R = 0.793), ACI% and SVV (R = 0.809), and ACI% and SPV [R = 0.766). No correlation with central venous pressure and pulmonary capillary wedge pressure was found. Conclusions: Dynamic parameters of fluid responsiveness by LiDCO are highly sensitive for assessment of intravascular volume status during OPCAB surgery. In contrast, even if static parameters by TEE reflect changes in ventricular diastolic volume, they are poor indicators of fluid responsiveness. Surprisingly, no significant correlation between Delta VAo (TEE) and ACI% was found. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 21 条
[11]   Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery [J].
Reuter, DA ;
Felbinger, TW ;
Schmidt, C ;
Kilger, E ;
Goedje, O ;
Lamm, P ;
Goetz, AE .
INTENSIVE CARE MEDICINE, 2002, 28 (04) :392-398
[12]   Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function [J].
Reuter, DA ;
Kirchner, A ;
Felbinger, TW ;
Weis, FC ;
Kilger, E ;
Lamm, P ;
Goetz, AE .
CRITICAL CARE MEDICINE, 2003, 31 (05) :1399-1404
[13]   Prediction of fluid responsiveness in patients during cardiac surgery [J].
Rex, S ;
Brose, S ;
Metzelder, S ;
Hüneke, R ;
Schälte, G ;
Autschbach, R ;
Rossaint, R ;
Buhre, W .
BRITISH JOURNAL OF ANAESTHESIA, 2004, 93 (06) :782-788
[14]  
RHODES A, 2004, INTENSIVE CARE EMERG, V42, P183
[15]   A RE-EVALUATION OF THE HEMODYNAMIC CONSEQUENCES OF INTERMITTENT POSITIVE PRESSURE VENTILATION [J].
ROBOTHAM, JL ;
CHERRY, D ;
MITZNER, W ;
RABSON, JL ;
LIXFELD, W ;
BROMBERGERBARNEA, B .
CRITICAL CARE MEDICINE, 1983, 11 (10) :783-793
[16]  
ROBOTHAM JL, 1983, CLIN CHEST MED, V4, P161
[17]   RELIABILITY OF CLINICAL MONITORING TO ASSESS BLOOD-VOLUME IN CRITICALLY ILL PATIENTS [J].
SHIPPY, CR ;
APPEL, PL ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1984, 12 (02) :107-112
[18]  
STETZ CW, 1982, AM REV RESPIR DIS, V126, P1001
[19]   Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension [J].
Tavernier, B ;
Makhotine, O ;
Lebuffe, G ;
Dupont, J ;
Scherpereel, P .
ANESTHESIOLOGY, 1998, 89 (06) :1313-1321
[20]   The use of transesophageal echocardiography for preload assessment in critically ill patients [J].
Tousignant, CP ;
Walsh, F ;
Mazer, CD .
ANESTHESIA AND ANALGESIA, 2000, 90 (02) :351-355