Bio-effects and safety of low-intensity, low-frequency ultrasonic exposure

被引:209
作者
Ahmadi, Farzaneh [1 ]
McLoughlin, Ian V. [1 ]
Chauhan, Sunita [2 ]
ter-Haar, Gail [3 ]
机构
[1] Nanyang Technol Univ, Sch Comp Engn, Singapore 639798, Singapore
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
[3] Royal Marsden Hosp, Inst Canc Res, Joint Phys Dept, Sutton SM2 5PT, Surrey, England
基金
英国工程与自然科学研究理事会;
关键词
Hazard; Bio-effects; Low-frequency ultrasound; Sonophoresis; Mechanical index; Thermal index; GAS-BODY ACTIVATION; ACOUSTIC CAVITATION; DRUG-DELIVERY; THERAPEUTIC ULTRASOUND; TRANSDERMAL DELIVERY; IN-VITRO; SONOPHORESIS; SKIN; HAZARDS; PHACOEMULSIFICATION;
D O I
10.1016/j.pbiomolbio.2012.01.004
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
070307 [化学生物学]; 071010 [生物化学与分子生物学];
摘要
Low-frequency (LF) ultrasound (20-100 kHz) has a diverse set of industrial and medical applications. In fact, high power industrial applications of ultrasound mainly occupy this frequency range. This range is also used for various therapeutic medical applications including sonophoresis (ultrasonic transdermal drug delivery), dentistry, eye surgery, body contouring, the breaking of kidney stones and eliminating blood clots. While emerging LF applications such as ultrasonic drug delivery continue to be developed and undergo translation for human use, significant gaps exist in the coverage of safety standards for this frequency range. Accordingly, the need to understand the biological effects of LF ultrasound is becoming more important. This paper presents a broad overview of bio-effects and safety of LF ultrasound as an aid to minimize and control the risk of these effects. Its particular focus is at low intensities where bio-effects are initially observed. To generate a clear perspective of hazards in LF exposure, the mechanisms of bio-effects and the main differences in action at low and high frequencies are investigated and a survey of harmful effects of LF ultrasound at low intensities is presented. Mechanical and thermal indices are widely used in high frequency diagnostic applications as a means of indicating safety of ultrasonic exposure. The direct application of these indices at low frequencies needs careful investigation. In this work, using numerical simulations based on the mathematical and physical rationale behind the indices at high frequencies, it is observed that while thermal index (TI) can be used directly in the LF range, mechanical index (MI) seems to become less reliable at lower frequencies. Accordingly, an improved formulation for the MI is proposed for frequencies below 500 kHz. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:119 / 138
页数:20
相关论文
共 149 条
[1]
ACGIH, 2001, AM C GOVT IND HYG CI
[2]
ACTON W. I., 1968, ANN OCCUP HYG, V11, P227
[3]
Acton W.I., 1977, PROTECTION, V14, P12
[4]
ACTON WI, 1983, J SOC OCCUP MED, V33, P107
[5]
EFFECTS OF INDUSTRIAL AIRBORN ULTRASOUND ON HUMANS [J].
ACTON, WI .
ULTRASONICS, 1974, 12 (03) :124-128
[6]
ACTON WI, 1967, BRIT J IND MED, V24, P297
[7]
Ahmadi F., 2009, RECENT ADV SIGNAL PR
[8]
SOME BIOLOGICAL EFFECTS OF INTENSE HIGH FREQUENCY AIRBORNE SOUND [J].
ALLEN, CH ;
FRINGS, H ;
RUDNICK, I .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1948, 20 (01) :62-65
[9]
[Anonymous], 1984, Health Phys, V46, P969
[10]
[Anonymous], 2000, Journal of Ultrasound in Medicine, V19, P97, DOI [DOI 10.7863/JUM.2000.19.2.97, 10.7863/jum.2000.19.2.97]