The improved potentiometric pH response of electrodes modified with processible polyaniline. Application to glucose biosensor

被引:40
作者
Karyakin, AA [1 ]
Lukachova, LV
Karyakina, EE
Orlov, AV
Karpachova, GP
机构
[1] Moscow MV Lomonosov State Univ, Fac Chem, Moscow 119899, Russia
[2] Russian Acad Sci, AV Topchiev Petrochem Synth Inst, Moscow 117912, Russia
来源
ANALYTICAL COMMUNICATIONS | 1999年 / 36卷 / 04期
关键词
D O I
10.1039/a900597h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Processible polyaniline (PCPAn) modified electrodes are characterized by an advanced potentiometric pH response in comparison to those based on regular polyaniline. Glassy carbon electrodes modified with PCPAn by dip-coating exhibited a fully reversible potentiometric response of approximately 90 mV pH(-1) over the range pH 3-9. Such significantly higher potentiometric responses of PCPAn modified electrodes compared to existing devices is explained on the basis of the thermodynamics of polyaniline redox reactions. The potentiometric biosensor for glucose based on processible polyaniline has been developed using a non-aqueous enzymology approach for enzyme immobilization. In the model solution, which mimics blood serum, the biosensor was useful for glucose detection over the concentration range 0.1-30 mM and the maximum response value reached was approximate to 80 mV. The advanced potentiometric response of PCPAn modified electrodes provides their application for sensor and biosensor development.
引用
收藏
页码:153 / 156
页数:4
相关论文
共 24 条
[1]   POLYANILINE THIN-FILMS FOR GAS-SENSING [J].
AGBOR, NE ;
PETTY, MC ;
MONKMAN, AP .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 28 (03) :173-179
[2]   EFFECT OF SOLVENTS AND COSOLVENTS ON THE PROCESSIBILITY OR POLYANILINE .1. SOLUBILITY AND CONDUCTIVITY STUDIES [J].
CAO, Y ;
QIU, JJ ;
SMITH, P .
SYNTHETIC METALS, 1995, 69 (1-3) :187-190
[3]   COUNTERION INDUCED PROCESSIBILITY OF CONDUCTING POLYANILINE [J].
CAO, Y ;
SMITH, P ;
HEEGER, AJ .
SYNTHETIC METALS, 1993, 57 (01) :3514-3519
[4]   ELECTROACTIVE POLYANILINE FILMS [J].
DIAZ, AF ;
LOGAN, JA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 111 (01) :111-114
[5]   Development and calibration of field-effect transistor-based sensor array for measurement of hydrogen and ammonia gas mixtures in humid air [J].
Domansky, K ;
Baldwin, DL ;
Grate, JW ;
Hall, TB ;
Li, J ;
Josowicz, M ;
Janata, J .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :473-481
[6]   INFLUENCE OF OXIDATION-STATE, PH, AND COUNTERION ON THE CONDUCTIVITY OF POLYANILINE [J].
FOCKE, WW ;
WNEK, GE ;
WEI, Y .
JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (22) :5813-5818
[7]   BIOSENSOR BASED ON CONDUCTING POLYMERS [J].
HOA, DT ;
KUMAR, TNS ;
PUNEKAR, NS ;
SRINIVASA, RS ;
LAL, R ;
CONTRACTOR, AQ .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2645-2646
[8]   POLYANILINE, A NOVEL CONDUCTING POLYMER - MORPHOLOGY AND CHEMISTRY OF ITS OXIDATION AND REDUCTION IN AQUEOUS-ELECTROLYTES [J].
HUANG, WS ;
HUMPHREY, BD ;
MACDIARMID, AG .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :2385-&
[9]   Potentiometric biosensors based on polyaniline semiconductor films [J].
Karyakin, AA ;
Bobrova, OA ;
Luckachova, LV ;
Karyakina, EE .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) :34-38
[10]   The influence of defects in polyaniline structure on its electroactivity: Optimization of 'self-doped' polyaniline synthesis [J].
Karyakin, AA ;
Maltsev, IA ;
Lukachova, LV .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 402 (1-2) :217-219