An experimental study of the utilization of heat pipes for solar water heaters

被引:71
作者
Chun, W [1 ]
Kang, YH [1 ]
Kwak, HY [1 ]
Lee, YS [1 ]
机构
[1] Cheju Natl Univ, Dept Nucl & Energy Engn, Cheju 690756, South Korea
关键词
heat pipes; solar water heater; experimental study; thermal performance;
D O I
10.1016/S1359-4311(98)00096-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper reports the performance of solar domestic hot water systems manufactured with heat pipes. A series of tests were conducted on a number of systems to elicit the most suitable configuration of the system for possible commercialization in Korea. The heat pipe is made with a copper tube and the respective lengths of the evaporator, adiabatic, and condenser sections are 1700, 100 and 200 mm. The evaporator section is finned with a copper plate to increase solar input. Results show interesting performance data stemming from the difference in working fluids, presence of a wick, and other various design parameters associated with the collection and utilization of solar energy. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:807 / 817
页数:11
相关论文
共 7 条
[1]  
ABHAT A, 1982, J ENERGY, V6
[2]  
Chi S.W., 1976, HEAT PIPE THEORY PRA
[3]  
Chun W.G., 1993, P 1 KOR IT JOINT WOR
[4]  
Dunn P.D., 1978, HEAT PIPES
[5]  
JANG YS, 1996, P 2 HEAT PIP WORKSH
[6]  
LEE YS, 1995, SOLAR ENERGY, V15
[7]  
RICHTER R, 1990, P AIAA ASME 5 JOINT