Simulation of the heating performance of the Kang system in one Chinese detached house using biomass

被引:31
作者
Cao, Guangyu [1 ]
Jokisalo, Juha [2 ]
Feng, Guohui [3 ]
Duanmu, Lin [4 ]
Vuolle, Mika [5 ]
Kurnitski, Jarek [6 ]
机构
[1] Tech Res Ctr Finland VIT, FI-02044 Espoo, Finland
[2] Aalto Univ, Dept Energy Technol, Espoo 02150, Finland
[3] Shenyang Jianzhu Univ, Municipal & Environm Engn Fac, Shenyang 110168, Peoples R China
[4] Dalian Univ Technol, Sch Civil & Hydraul Engn, Dalian 110024, Peoples R China
[5] EQUA Simulat Oy, Espoo 02210, Finland
[6] Finnish Innovat Fund, Helsinki 00181, Finland
关键词
Building simulation; Heating performance; Detached house; Kang; Thermal comfort; Occupant behaviour; Biomass; THERMAL COMFORT; BUILDINGS;
D O I
10.1016/j.enbuild.2010.09.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A traditional Chinese heating system the Chinese Kang is used by 175 million people in detached houses in the rural regions of China especially in Northeast China This system utilizes biomass such as corn stalks straw corncob and energy plants as the heat sources The objective of this paper is to establish a set of models to simulate the energy performance of the Kang heating system in one Chinese detached house An experimental field study was carried out to collect practical parameters in a newly constructed Chinese detached house The dynamic performance of the Kang heating system was simulated by using IDA-ICE 40 embedded with an empirical model built in the field study The results show that the simulation can obtain good overall agreement with the field measurement results It was confirmed that the Kang model created by IDA-ICE 40 is capable of simulating the performance of the Kang system and of calculating energy consumption in the detached house Moreover the result reveals that the thermal environment in the present Chinese detached house is still poor during the severe cold season if only the Kang system is used to heat the whole house (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:189 / 199
页数:11
相关论文
共 43 条
[1]  
Achermann M., 2003, RADTEST RADIANT HEAT
[2]  
[Anonymous], RENEW ENERGY, DOI DOI 10.13941/J.CNKI.21-1469/TK.2003.03.023
[3]  
[Anonymous], NEW AGR
[4]  
[Anonymous], 1993, GB50176-93
[5]  
[Anonymous], Statistics Finland
[6]  
[Anonymous], 2005, Ergonomics of the thermal environment _ Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
[7]  
[Anonymous], 2004, 13791 EN ISO
[8]  
ASHRAE, 2004, Standard 55-2020
[9]  
Bansal N.K., 1998, BUILD ENVIRON, V34, P305
[10]   Air flows in dwellings -: simulations and measurements [J].
Blomsterberg, Å ;
Carlsson, T ;
Svenson, C ;
Kronvall, J .
ENERGY AND BUILDINGS, 1999, 30 (01) :87-95