Determination of platinum in rat dorsal root ganglion using ICP-MS

被引:15
作者
Ding, H
Goldberg, MM
Raymer, JH
Holmes, J
Stanko, J
Chaney, SG
机构
[1] Res Triangle Inst, Res Triangle Pk, NC 27709 USA
[2] Univ N Carolina, Sch Med, Dept Biochem & Biophys, Chapel Hill, NC 27599 USA
关键词
platinum; cisplatin; neurotoxicity; inductively coupled plasma mass spectrometry; flow injection analysis;
D O I
10.1007/BF02784270
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study evaluated the performance of inductively coupled plasma mass spectrometry for the determination of platinum (Pt) in rat dorsal root ganglion. The method detection limit was found to be 0.008 ng/mL of Pt, which corresponds to 4 pg of Pt per milligram of ganglia. The standard deviations in the tissue matrix were 5.7% or better and minimum matrix effect was observed. Compared to indium, the use of iridium or a combination of iridium and bismuth as internal standard(s) provided more accurate measurement. The Pt in the tissue digestate was stable for a minimum of 46 d at levels above 0.05 ng/mL. Flow injection analysis using undiluted digestates resulted in approximately 20% signal enhancement. Internal standard correction was necessary to obtain accurate results. The method was used in initial studies in which rats were dosed with cisplatin and has shown that Pt accumulates and persists in dorsal rat ganglion following treatment.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 26 条
[1]   EVALUATION OF INDUCTIVELY COUPLED MASS-SPECTROMETRY FOR THE DETERMINATION OF PLATINUM IN PLASMA [J].
ALLAIN, P ;
BERRE, S ;
MAURAS, Y ;
LEBOUIL, A .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (03) :141-143
[2]  
BOORN A, 1985, MIKROCHIM ACTA, V2, P171
[3]   DETERMINATION OF ARSENIC IN SAMPLES WITH HIGH CHLORIDE CONTENT BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BRANCH, S ;
EBDON, L ;
FORD, M ;
FOULKES, M ;
ONEILL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :151-154
[4]  
CASETTA B, 1991, ATOM SPECTROSC, V12, P81
[5]   ACID EFFECTS IN ICP-AES [J].
CHUDINOV, EG ;
OSTROUKHOVA, II ;
VARVANINA, GV .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (01) :25-33
[6]   SELECTION OF MODE FOR THE MEASUREMENT OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY AND ITS APPLICATION TO MILK POWDER ANALYSIS [J].
DEAN, JR ;
EBDON, L ;
MASSEY, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (04) :369-374
[7]   NEBULIZATION EFFECTS WITH ACID SOLUTIONS IN ICP SPECTROMETRY [J].
GREENFIELD, S ;
MCGEACHIN, HM ;
SMITH, PB .
ANALYTICA CHIMICA ACTA, 1976, 84 (01) :67-78
[8]   CISPLATIN NEUROTOXICITY - THE RELATIONSHIP BETWEEN DOSAGE, TIME, AND PLATINUM CONCENTRATION IN NEUROLOGIC TISSUES, AND MORPHOLOGICAL EVIDENCE OF TOXICITY [J].
GREGG, RW ;
MOLEPO, JM ;
MONPETIT, VJA ;
MIKAEL, NZ ;
REDMOND, D ;
GADIA, M ;
STEWART, DJ .
JOURNAL OF CLINICAL ONCOLOGY, 1992, 10 (05) :795-803
[10]  
HUTTON RC, 1986, PQ704 VG IS LTD