Heatline Analysis for Natural Convection within Porous Rhombic Cavities with Isothermal/Nonisothermal Hot Bottom Wall

被引:18
作者
Anandalakshmi, R. [1 ]
Basak, Tanmay [1 ]
机构
[1] Indian Inst Technol, Dept Chem Engn, Madras 600036, Tamil Nadu, India
关键词
MASS-TRANSFER; THERMAL-CONVECTION; FLOW VISUALIZATION; NUMERICAL-ANALYSIS; FORCED-CONVECTION; BEJANS HEATLINES; ENCLOSURE; TEMPERATURE; STREAMLINE; FLUID;
D O I
10.1021/ie2007856
中图分类号
TQ [化学工业];
学科分类号
081705 [工业催化];
摘要
Analysis has been carried out for energy distribution and thermal mixing in steady laminar natural convective flow through the porous rhombic cavities with inclination angle phi for various applications such as geothermal, grain storage, electronic cooling, etc. A generalized non-Darcy model without the Forchheimer inertia term is used to predict the flow in porous media. The effect of the Darcy number (Da) and the role of phi on the energy distribution and thermal mixing within porous rhombic cavities with isothermal (case 1) and nonisothermal (case 2) hot bottom walls are illustrated via "heatlines". Heat transfer is found to be primarily conduction dominant at Da = 10(-5) even at a higher Rayleigh number (Ra = 10(6)). The onset of convection occurs at Da = 10(-4), and the distorted heatlines from the hot bottom wall take a longer path to reach the cold side walls of the cavity. Larger heat transfer and thermal mixing occurs for Da = 10(-3) at Ra = 10(6) irrespective of phi and Pr. Multiple flow/convective circulations are observed at Pr = 0.015 for all phi values at Da = 10(-3). On the other hand, two asymmetric flow circulation cells are found to occupy the entire cavity at Pr = 0.7, 7.2, and 1000 for phi = 75 degrees at Da = 10(-3). The cavity with inclination angle phi = 30 degrees enhances the convective heat transfer from the hot wall to the cold wall, and the heat transfer to the right cold wall is a maximum for phi = 75 degrees, as depicted by "heatlines" irrespective of Pr at Da = 10(-3). Average Nusselt number studies based on heatfunction gradients also show that the cavity with phi = 30 degrees gives a maximum heat-transfer rate from the bottom to the left wall irrespective of Pr in case 1 at Da = 10(-3). The cup mixing temperature (Theta(cup)) is higher for case 1 compared to case 2, and it is almost invariant with phi for higher Pr (Pr = 7.2 and 1000) in case 1 at Da = 10(-3).
引用
收藏
页码:2113 / 2132
页数:20
相关论文
共 75 条
[1]
Heat transfer in a conical cylinder with porous medium [J].
Ahmed, N. J. Salman ;
Badruddin, Irfan Anjum ;
Zainal, Z. A. ;
Khaleed, H. M. T. ;
Kanesan, Jeevan .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (13-14) :3070-3078
[2]
Modelling turbulent flow and heat transfer using macro-porous media approach used to predict cooling kinetics of stack of food products [J].
Alvarez, G. ;
Flick, D. .
JOURNAL OF FOOD ENGINEERING, 2007, 80 (02) :391-401
[3]
[Anonymous], VISCOUS FLUID FLOW
[4]
Role of 'Bejan's heatlines' in heat flow visualization and optimal thermal mixing for differentially heated square enclosures [J].
Basak, Tanmay ;
Roy, S. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (13-14) :3486-3503
[5]
Analysis of heatlines for natural convection within porous trapezoidal enclosures: Effect of uniform and non-uniform heating of bottom wall [J].
Basak, Tanmay ;
Roy, S. ;
Matta, Anjanna ;
Pop, I. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (25-26) :5947-5961
[6]
Batchelor G.K., 1993, An introduction to fluid dynamics
[7]
Free convection in oblique enclosures filled with a porous medium [J].
Baytas, AC ;
Pop, I .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (06) :1047-1057
[8]
Free convection in a square porous cavity using a thermal nonequilibrium model [J].
Baytas, AC ;
Pop, L .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (09) :861-870
[10]
BOUNDARY-LAYER REGIME IN A VERTICAL ENCLOSURE FILLED WITH A POROUS-MEDIUM [J].
BEJAN, A .