CT iterative reconstruction in image space: A phantom study

被引:74
作者
Ghetti, C. [1 ]
Ortenzia, O. [1 ]
Serreli, G. [1 ]
机构
[1] Univ Parma, Azienda Osped, Serv Fis Sanit, I-43100 Parma, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2012年 / 28卷 / 02期
关键词
Iterative reconstruction; Image quality; Computed tomography;
D O I
10.1016/j.ejmp.2011.03.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Although iterative reconstruction is widely applied in SPECT/PET, its introduction in clinical CT is quite recent, in the past the demand for extensive computer power and long image reconstruction times have stopped the diffusion of this technique. Recently Iterative Reconstruction in Image Space (IRIS) has been introduced on Siemens top CT scanners. This recon method works on image data area, reducing the time-consuming loops on raw data and noise removal is obtained in subsequent iterative steps with a smoothing process. We evaluated image noise, low contrast resolution, CT number linearity and accuracy, transverse and z-axis spatial resolution using some dedicated phantoms in single, dual source and cardiac mode. We reconstructed images with a traditional filtered back-projection algorithm and with IRIS. The iterative procedure preserves spatial resolution, CT number accuracy and linearity moreover decreases image noise. These preliminary results support the idea that dose reduction with preserved image quality is possible with IRIS, even if studies on patients are necessary to confirm these data. (C) 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 13 条
[1]
[Anonymous], IT REC IM SPAC
[2]
Bittencourt MS, 2010, INT J CARDIOVAS 1201
[3]
Application of the noise power spectrum in modern diagnostic MDCT: Part II. Noise power spectra and signal to noise [J].
Boedeker, K. L. ;
McNitt-Gray, M. F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14) :4047-4061
[4]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]
Computed tomography-old ideas and new technology [J].
Fleischmann, Dominik ;
Boas, F. Edward .
EUROPEAN RADIOLOGY, 2011, 21 (03) :510-517
[6]
Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality [J].
Flohr, Thomas G. ;
Leng, Shuai ;
Yu, Lifeng ;
Allmendinger, Thomas ;
Bruder, Herbert ;
Petersilka, Martin ;
Eusemann, Christian D. ;
Stierstorfer, Karl ;
Schmidt, Bernhard ;
McCollough, Cynthia H. .
MEDICAL PHYSICS, 2009, 36 (12) :5641-5653
[7]
LANGE K, 1984, J COMPUT ASSIST TOMO, V8, P306
[8]
Strategies for Reducing Radiation Dose in CT [J].
McCollough, Cynthia H. ;
Primak, Andrew N. ;
Braun, Natalie ;
Kofler, James ;
Yu, Lifeng ;
Christner, Jodie .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) :27-+
[9]
Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction? [J].
Pan, Xiaochuan ;
Sidky, Emil Y. ;
Vannier, Michael .
INVERSE PROBLEMS, 2009, 25 (12)
[10]
Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients [J].
Pontana, Francois ;
Pagniez, Julien ;
Flohr, Thomas ;
Faivre, Jean-Baptiste ;
Duhamel, Alain ;
Remy, Jacques ;
Remy-Jardin, Martine .
EUROPEAN RADIOLOGY, 2011, 21 (03) :627-635