Automated prostate localization in external-beam radiotherapy using mutual information-based registration of treatment planning CT and daily 3D ultrasound images

被引:9
作者
Castro-Pareja, CR [1 ]
Zagrodsky, V [1 ]
Bouchet, L [1 ]
Shekhar, R [1 ]
机构
[1] Univ Maryland, Med Ctr, Dept Diagnost Radiol, College Pk, MD 20742 USA
来源
CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY | 2005年 / 1281卷
关键词
external beam radiotherapy; image registration; anisotropic diffusion filtering; 3D ultrasound; CT; prostate cancer;
D O I
10.1016/j.ics.2005.03.115
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The accuracy of mutual information-based registration for automatic alignment of planning CT and daily 3D ultrasound images is evaluated. The results show the importance of preprocessing both the CT and the daily 3D ultrasound images to maximize registration accuracy. Contours traced by experts for treatment planning were used as a priori information for contrast enhancement in the CT images. Furthermore, the CT and daily 3D ultrasound datasets were filtered using edge preserving anisotropic diffusion filtering. The Study also compared the accuracy of rigid registration with three or six degrees of freedom against elastic registration based on a deformation field modelled using B-Splines. Experiments with clinical images of wide ranging image quality acquired using a SonArray (TM) system achieved Success ratios in estimating the prostate shifts of 80%, 60% and 93% for rigid registration with three or six degrees of freedom and elastic registration respectively. (c) 2005 CARS & Elsevier B.V. All rights reserved.
引用
收藏
页码:435 / 440
页数:6
相关论文
共 12 条
[1]  
[Anonymous], CANC FACTS FIG 2004
[2]   FPGA-based real-time anisotropic diffusion filtering of 3D ultrasound images [J].
Castro-Pareja, CR ;
Dandekar, O ;
Shekhar, R .
REAL-TIME IMAGING IX, 2005, 5671 :123-131
[3]  
CASTROPAREJA CR, 2005, P SOC PHOTO-OPT INS, P5747
[4]  
Dorati A, 1995, COMPUT CARDIOL, P565, DOI 10.1109/CIC.1995.482727
[5]   Mutual information based registration for ultrasound and CT datasets [J].
Firle, EA ;
Wesarg, S ;
Dold, C .
MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 :1130-1138
[6]  
Gibson S. F. F., 1997, Proceedings 1997 Symposium on Interactive 3D Graphics, P149, DOI 10.1145/253284.253324
[7]   A SIMPLEX-METHOD FOR FUNCTION MINIMIZATION [J].
NELDER, JA ;
MEAD, R .
COMPUTER JOURNAL, 1965, 7 (04) :308-313
[8]   Mutual-information-based registration of medical images: A survey [J].
Pluim, JPW ;
Maintz, JBA ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (08) :986-1004
[9]   Nonrigid registration using free-form deformations: Application to breast MR images [J].
Rueckert, D ;
Sonoda, LI ;
Hayes, C ;
Hill, DLG ;
Leach, MO ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (08) :712-721
[10]   Prostate localization using transabdominal ultrasound imaging [J].
Trichter, F ;
Ennis, RD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (05) :1225-1233