Changes in systolic and diastolic function during multivessel off-pump coronary bypass grafting

被引:19
作者
Biswas, S
Clements, F
Diodato, L
Hughes, GC
Landolfo, K
机构
[1] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Anesthesia, Durham, NC 27710 USA
关键词
off-pump coronary bypass grafting; left ventricular function;
D O I
10.1016/S1010-7940(01)00932-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To measure the changes in systolic and diastolic left ventricular function that occur during off-pump coronary artery bypass grafting (OPCAB) as a consequence of positioning the heart and interrupting coronary flow. Methods: 2-D Transoesophageal echocardiography was used to derive systolic wall motion indices and pulsed Doppler parameters of diastolic function including the E/A ratio, PVS/ PVD ratio, and deceleration time. A continuous cardiac output thermodilution pulmonary artery catheter was used to provide hemodynamic measures of left ventricular function. Data was obtained prior to, during and following coronary grafting. Results: Thirty-four consecutive anastomoses were evaluated, including eight circumflex (LCX), 17 left anterior descending artery (LAD) and nine right coronary artery (RCA) anastamoses. Significant changes in diastolic and systolic cardiac function were identified in those patients who underwent LCX grafting. Specifically during LCX grafting, both wall motion score index (2.4 +/- 1.4 vs 1.5 +/- 0.63 and 1.9 +/- 0.91) and the E/A ratio were significantly increased (3.5 +/- 1.4 vs 1.5 +/- 0.33 and 1.2 +/- 0.44) when compared to RCA and LAD grafting, respectively. The PVS/PVD ratio was significantly decreased during left circumflex grafting (0.7 +/- 0.45 vs 1.1 +/- 0.19 and 1.0 +/- 0.58) when compared to RCA and LAD grafting, respectively. All functional parameters returned to baseline by the end of surgery. Conclusions: Multivessel OPCAB can be achieved with mild impairment of left ventricular function that returns to baseline by the end of the procedure. Impairment of diastolic function is most marked during circumflex grafting as demonstrated by a restrictive filling pattern. Measures of diastolic function may be helpful in developing better strategies for exposure of the circumflex graft site. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:913 / 917
页数:5
相关论文
共 7 条
[1]   Left ventricular geometry and cardiac function during minimally invasive coronary artery bypass grafting [J].
Jurmann, MJ ;
Menon, AK ;
Haeberle, L ;
Salehi-Gilani, S ;
Ziemer, G .
ANNALS OF THORACIC SURGERY, 1998, 66 (03) :1082-1086
[2]  
Krucylak P E, 1999, Semin Thorac Cardiovasc Surg, V11, P116
[3]   Importance of intraoperative transesophageal echocardiography during coronary artery surgery without cardiopulmonary bypass [J].
Moisés, VA ;
Mesquita, CB ;
Campos, O ;
Andrade, JL ;
Bocanegra, J ;
Andrade, JCS ;
Buffolo, E ;
Carvalho, AC .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (12) :1139-1144
[4]   Off-pump multivessel coronary bypass via sternotomy is safe and effective [J].
Puskas, JD ;
Wright, CE ;
Ronson, RS ;
Brown, WM ;
Gott, JP ;
Guyton, RA .
ANNALS OF THORACIC SURGERY, 1998, 66 (03) :1068-1072
[5]  
RAKOWSKI H, 1996, J AM SOC ECHOCARDIOG, V9, P154
[6]   Minimally invasive coronary artery bypass grafting:: Port-access approach versus off-pump techniques [J].
Reichenspurner, H ;
Boehm, DH ;
Welz, A ;
Schmitz, C ;
Wildhirt, S ;
Schulze, C ;
Meiser, B ;
Schütz, A ;
Reichart, B .
ANNALS OF THORACIC SURGERY, 1998, 66 (03) :1036-1040
[7]   ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination:: Recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography [J].
Shanewise, JS ;
Cheung, AT ;
Aronson, S ;
Stewart, WJ ;
Weiss, RL ;
Mark, JB ;
Savage, RM ;
Sears-Rogan, P ;
Mathew, JP ;
Quiñones, MA ;
Cahalan, MK ;
Savino, JS .
ANESTHESIA AND ANALGESIA, 1999, 89 (04) :870-884