Effect of polymerization methods on the residual monomer level of acrylic resin denture base polymers

被引:24
作者
Celebi, Niluefer [2 ]
Yuzugullu, Bulem [1 ]
Canay, Senay [2 ]
Yucel, Ulku [3 ]
机构
[1] Baskent Univ, Dept Prosthodont, Fac Dent, TR-06490 Ankara, Turkey
[2] Univ Hacettepe, Dept Prosthodont, Fac Dent, TR-06100 Ankara, Turkey
[3] Saraykoy Nucl Res & Training Ctr, Ankara, Turkey
关键词
high performance liquid chromatography; injection molding; microwave polymerization; compression molding; monomer;
D O I
10.1002/pat.996
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 [高分子化学与物理]; 080501 [材料物理与化学]; 081704 [应用化学];
摘要
Wearing dental acrylic prosthesis causes adverse reactions to oral tissues due to bioactive leachables from resins such as residual methyl methacrylate (MMA). The aim of this study is to apply the high performance liquid chromatography (HPLC) method to quantify and compare the amount of MMA monomers released from denture base resin polymers processed by the conventional compression molding method (Paladent), microwave polymerization (Acron MC), and injection molding technique (PalaXpress). Six specimens of 10 +/- 0.2 mm in diameter and 2.0 +/- 0.2 mm in thickness of each material were prepared according to manufacturer's instructions. Specimens were stored in nanopure water at room temperature (23 +/- 2 degrees C) for 4 hr, 48 hr, 8 days, and 15 days separately. Residual MMA released into water was determined with HPLC for all time intervals. Data for all time intervals were analyzed among each group using the Friedman test and differences were found to be statistically significant for all time intervals for Acron MC, Paladent, and PalaXpress (p > 0.05). Kruskal-Wallis test was used to compare changes of residual MMA within time intervals among denture base resin groups and statistically significant differences were found between all time intervals (p > 0.05). Acron MC exhibited significantly lower residual MMA leach compared both to Paladent and PalaXpress, and Paladent showed more residual MMA leach compared to PalaXpress. Residual MMA leach for Acron MC, PalaXpress, and Paladent showed statistically significant leach in the first 48 hr of immersion in water followed by gradual longer-lasting moderate increase until the 15 day interval which was not statistically significant (p < 0.05). Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:201 / 206
页数:6
相关论文
共 28 条
[1]
ALDOORI D, 1988, DENT MATER, V4, P25
[2]
Techniques for reducing residual monomer content in polymers:: A review [J].
Araújo, PHH ;
Sayer, C ;
Poço, JGR ;
Giudici, R .
POLYMER ENGINEERING AND SCIENCE, 2002, 42 (07) :1442-1468
[3]
The effect of post-cure heating on residual, unreacted monomer in a commercial resin composite [J].
Bagis, YH ;
Rueggeberg, FA .
DENTAL MATERIALS, 2000, 16 (04) :244-247
[4]
Effects of water storage of e-glass fiber reinforced denture base polymers on residual methyl methacrylate content [J].
Bayraktar, G ;
Duran, Z ;
Bural, C ;
Guvener, B .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 70B (01) :161-166
[5]
Botega Daniela Maffei, 2004, Braz. oral res., V18, P23, DOI 10.1590/S1806-83242004000100005
[6]
Cury AAD, 2001, J ORAL REHABIL, V28, P433
[7]
MICROWAVE POLYMERIZATION OF ACRYLIC RESINS USED IN DENTAL PROSTHESES [J].
DECLERCK, JP .
JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (05) :650-658
[8]
ALLERGIC CONTACT STOMATITIS CAUSED BY ACRYLIC RESIN [J].
GIUNTA, JL ;
GRAUER, I ;
ZABLOTSKY, N .
JOURNAL OF PROSTHETIC DENTISTRY, 1979, 42 (02) :188-190
[9]
Jorge JH, 2004, INT J PROSTHODONT, V17, P340
[10]
Cytotoxicity of denture base acrylic resins: A literature review [J].
Jorge, JH ;
Giampaolo, ET ;
Machado, AL ;
Vergani, CE .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (02) :190-193