Determination of triazine compounds in ground water samples by micellar electrokinetic capillary chromatography

被引:56
作者
Frías, S [1 ]
Sánchez, MJ [1 ]
Rodríguez, MA [1 ]
机构
[1] Univ La Laguna, Dept Analyt Chem Nutr & Food Sci, San Cristobal la Laguna 38071, Spain
关键词
triazine compounds; SDS micelles; organic modifiers; ground water samples;
D O I
10.1016/j.aca.2003.10.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a capillary electrophoresis (CE) method for the determination of a group of eleven triazine compounds by micellar electrokinetic capillary chromatography (MEKC) with diode array detection was developed. The eleven herbicides studied were: desethylatrazin-2-hydroxy (DEA), simazine. prometon, atrazine, simetryn, ametryn, propazine, prometryn, trietazine, terbutylazine, and terbutryn The separation of these compounds was optimised as a function of buffer concentration and pH, concentration of sodium dodecyl sulphate (SDS) and voltage applied. To increase the selectivity of the separation and the resolution of the solutes, different organic solvents were tested as buffer additives, obtaining the best results when 1-propanol was used. The optimised buffer (24 mM of sodium borate, 18 mM of disodium hydrogen phosphate, 25 mM of SDS, pH 9.5. and 5% of 1-propanol) provides the best separation in terms of resolution and migration time. This method allowed the determination of these compounds at concentrations of 0.05 mug l(-1) in ground water samples pretreated using solid-phase extraction (SPE). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 39 条
  • [1] Aelion CM, 2001, ENVIRON TOXICOL CHEM, V20, P2411, DOI [10.1002/etc.5620201103, 10.1897/1551-5028(2001)020&lt
  • [2] 2411:ABTDAD&gt
  • [3] 2.0.CO
  • [4] 2]
  • [5] [Anonymous], 1998, FED REG, V63, P10274
  • [6] Determination of trans-resveratrol and other polyphenols in wines by a continuous flow sample clean-up system followed by capillary electrophoresis separation
    Arce, L
    Tena, MT
    Rios, A
    Valcárcel, M
    [J]. ANALYTICA CHIMICA ACTA, 1998, 359 (1-2) : 27 - 38
  • [7] Trace determination of priority pesticides in water by means of high-speed on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry using turbulent-flow chromatography columns for enrichment and a short monolithic column for fast liquid chromatographic separation
    Asperger, A
    Efer, J
    Koal, T
    Engewald, W
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) : 109 - 119
  • [8] Optimization of the separation of Vinca alkaloids by nonaqueous capillary electrophoresis
    Barthe, L
    Ribet, JP
    Pélissou, M
    Degude, MJ
    Fahy, J
    Duflos, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 968 (1-2) : 241 - 250
  • [9] MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY OF NEUTRAL SOLUTES WITH MICELLES OF ADJUSTABLE SURFACE-CHARGE DENSITY
    CAI, J
    ELRASSI, Z
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2): : 31 - 45
  • [10] Evolution over time of the agricultural pollution of waters in an area of Salamanca and Zamora (Spain)
    Carabias-Martínez, R
    Rodríguez-Gonzalo, E
    Fernández-Laespada, ME
    Calvo-Seronero, L
    Sánchez-San Román, FJ
    [J]. WATER RESEARCH, 2003, 37 (04) : 928 - 938