Sensitive and selective determination of mercury by differential pulse stripping voltammetry after accumulation of mercury vapour on a gold plated graphite electrode

被引:28
作者
Korolczuk, M
机构
[1] Faculty of Chemistry, Maria Curie Skłodowska University
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1997年 / 357卷 / 04期
关键词
D O I
10.1007/s002160050175
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective and sensitive method is proposed for the determination of mercury by anodic stripping voltammetry after its preconcentration from the gas phase. Mercury from the sample solution is reduced to elemental Hg by SnCl2 and volatilized by the bubbles of a carrier gas. The gas containing mercury vapour is dried and passed through a capillary onto a gold coated graphite electrode. An anodic stripping voltammogram is recorded from 0.1 mol/l HClO4 + 3x10(-3) mol/l HCl solution. The calibration curve is linear from 1x10(-9) to 4x10(-8) mol/l Hg(NO3)(2). The absolute detection limit is 0.46 ng Hg. The relative standard deviations for 4x10(-9) mol/l and 2x10(-8) mol/l Hg(NO3)(2) are 9.8% and 6.1%, respectively (n = 5).
引用
收藏
页码:389 / 391
页数:3
相关论文
共 27 条
[1]   EVALUATION OF SOME WET DECOMPOSITION METHODS FOR MERCURY DETERMINATION IN BIOLOGICAL AND ENVIRONMENTAL MATERIALS BY COLD VAPOR ATOMIC-ABSORPTION SPECTROSCOPY [J].
ADELOJU, SB ;
DHINDSA, HS ;
TANDON, RK .
ANALYTICA CHIMICA ACTA, 1994, 285 (03) :359-364
[2]   ADVANCED ELECTROANALYTICAL TECHNIQUES VERSUS ATOMIC-ABSORPTION SPECTROMETRY, INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY IN ENVIRONMENTAL-ANALYSIS [J].
BERSIER, PM ;
HOWELL, J ;
BRUNTLETT, C .
ANALYST, 1994, 119 (02) :219-232
[3]   VOLTAMMETRIC DETERMINATION OF TRACE AMOUNTS OF MERCURY WITH A CARBON PASTE ELECTRODE MODIFIED WITH AN ANION-EXCHANGER [J].
CAI, X ;
KALCHER, K ;
DIEWALD, W ;
NEUHOLD, C ;
MAGEE, RJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (01) :25-31
[4]   DETERMINATION OF MERCURY IN FOODSTUFFS [J].
COLES, LE ;
GUTHENBERG, H ;
KATO, T ;
KOJIMA, K .
PURE AND APPLIED CHEMISTRY, 1985, 57 (10) :1507-1514
[5]  
CUKROWSKI I, 1980, Patent No. 10655
[6]   DIRECT DETERMINATION OF MERCURY IN SEA-WATER BY ANODIC-STRIPPING VOLTAMMETRY WITH A GRAPHITE ELECTRODE [J].
FUKAI, R ;
HUYNHNGOC, L .
ANALYTICA CHIMICA ACTA, 1976, 83 (MAY) :375-379
[7]   VOLTAMMETRIC METHODS FOR DETERMINATION OF MERCURY IN DOMESTIC WASTE AND COMPOST [J].
GOLIMOWSKI, J ;
ORZECHOWSKA, A ;
TYKARSKA, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (07) :656-659
[8]   DETERMINATION OF MERCURY IN URINE BY FLOW-INJECTION COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
GUO, TZ ;
BAASNER, J .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :189-196
[9]   DETERMINATION OF MERCURY BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY WITH VARIOUS WORKING ELECTRODES - APPLICATION TO THE ANALYSIS OF NATURAL-WATER SEDIMENTS [J].
HATLE, M .
TALANTA, 1987, 34 (12) :1001-1007
[10]   FLOW POTENTIOMETRIC AND CONSTANT-CURRENT STRIPPING ANALYSIS FOR MERCURY(II) WITH GOLD, PLATINUM AND CARBON-FIBER WORKING ELECTRODES - APPLICATION TO THE ANALYSIS OF TAP WATER [J].
HUANG, HL ;
JAGNER, D ;
RENMAN, L .
ANALYTICA CHIMICA ACTA, 1987, 201 :1-9