Transpecies heart valve transplant: Advanced studies of a bioengineered xeno-autograft

被引:102
作者
Goldstein, S
Clarke, DR
Walsh, SP
Black, KS
O'Brien, MF
机构
[1] CryoLife Inc, Kennesaw, GA 30144 USA
[2] Univ Colorado, Hlth Sci Ctr, Denver, CO USA
[3] Prince Charles Hosp, Brisbane, Qld 4032, Australia
关键词
D O I
10.1016/S0003-4975(00)01812-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Tissue engineering approaches utilizing biomechanically suitable cell-conductive matrixes should extend xenograft heart valve performance, durability, and growth potential to an extent presently attained only by the pulmonary autograft. To test this hypothesis, we developed an acellular, unfixed porcine aortic valve-based construct. The performance of this valve has been evaluated in vitro under simulated aortic conditions, as a pulmonary valve replacement in sheep, and in aortic and pulmonary valve replacement in humans. Methods, SynerGraft porcine heart valves (CryoLife Inc, Kennesaw, GA) were constructed from porcine noncoronary aortic valve cusp units consisting of aorta, noncoronary aortic leaflet, and attached anterior mitral leaflet (AML). After treatment to remove all histologically demonstrable leaflet cells and substantially reduce porcine cell-related immunoreactivity, three Valve cusps were matched and sewn to form a symmetrical root utilizing the AML remnants as the inflow conduit. SynerGraft valves were evaluated by in vitro hydrodynamics, and by in vivo implants in the right ventricular outflow tract of weanling sheep for up to 336 days. Cryopreserved allograft valves served as control valves in both in vitro and in vivo evaluations. Valves were also implanted as aortic valve replacements in humans. Results. In vitro pulsatile now testing, of the SynerGraft porcine valves demonstrated excellent valve function with large effective orifice areas and low gradients equivalent to a normal human aortic valve. Implants in sheep right ventricular outflow tracts showed stable leaflets with up to 80% of matrix recellularization with host fibroblasts and/or myofibroblasts, and with no leaflet calcification over 150 days, and minimal deposition at 336 days. Echocardiography studies showed normal hemodynamic performance during the implantation period. The human implants have proven functional for over 9 months. Conclusions. A unique heart valve construct has been engineered to achieve the equivalent of an autograft. Short-term durability of these novel implants demonstrates for the first time the possibility of an engineered autograft. (Ann Thorac Surg 2000;70:1962-9) (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:1962 / 1969
页数:8
相关论文
共 23 条
[1]  
[Anonymous], BIOCH COLLAGEN
[2]   Postimplantation leaflet cellularity of valve allografts: Are donor cells beneficial or detrimental? [J].
Armiger, LC .
ANNALS OF THORACIC SURGERY, 1998, 66 (06) :S233-S235
[3]   PRESENCE OF A SMOOTH-MUSCLE SYSTEM IN AORTIC-VALVE LEAFLETS [J].
BAIRATI, A ;
DEBIASI, S .
ANATOMY AND EMBRYOLOGY, 1981, 161 (03) :329-340
[4]   A CLINICAL EXPERIENCE WITH BETAPROPIOLACTONE-STERILIZED HOMOLOGOUS AORTIC VALVE FOLLOWED UP TO 4 YEARS [J].
BARNES, RW ;
RITTENHOUSE, EA ;
MOHRI, H ;
MERENDINO, KA .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1970, 59 (06) :785-+
[5]  
BEACH PM, 1972, CIRCULATION S1, V40, P29
[6]  
BINET JP, 1965, LANCET, V2, P1275
[7]   BIOLOGICAL FACTORS AFFECTING LONG-TERM RESULTS OF VALVULAR HETEROGRAFTS [J].
CARPENTIER, A ;
LEMAIGRE, G ;
ROBERT, L ;
CARPENTIER, S ;
DUBOST, C ;
GERBODE, F .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (04) :467-+
[8]   FACTORS INFLUENCING MYOFIBROBLAST DIFFERENTIATION DURING WOUND-HEALING AND FIBROSIS [J].
DESMOULIERE, A .
CELL BIOLOGY INTERNATIONAL, 1995, 19 (05) :471-476
[9]   PULMONARY AUTOGRAFT IN CHILDREN - REALIZED GROWTH-POTENTIAL [J].
ELKINS, RC ;
KNOTTCRAIG, CJ ;
WARD, KE ;
MCCUE, C ;
LANE, MM .
ANNALS OF THORACIC SURGERY, 1994, 57 (06) :1387-1394
[10]  
GRIMM M, 1991, J THORAC CARDIOV SUR, V102, P195