Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report

被引:143
作者
Kambouroglou, GK [1 ]
Axelrod, TS [1 ]
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Dept Orthopaed Surg, Toronto, ON M4N 3M5, Canada
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 1998年 / 23A卷 / 04期
关键词
D O I
10.1016/S0363-5023(98)80063-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Two patients are reported who had tendon rupture and plate breakage following internal fixation with the newly designed AO/ASIF titanium distal radius plate system (rr plate). The incidence of complications with this system warrants further evaluation. (J Hand Surg 1998; 23A:737-741. Copyright (C) 1998 by the American Society for Surgery of the Hand.)
引用
收藏
页码:737 / 741
页数:5
相关论文
共 5 条
[1]
OPEN REDUCTION AND INTERNAL-FIXATION OF COMMINUTED, INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
AXELROD, TS ;
MCMURTRY, RY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :1-11
[2]
FERNANDEZ DL, 1993, ORTHOP CLIN N AM, V24, P341
[3]
Treatment of displaced intra-articular fractures of the distal end of the radius with plates [J].
Fitoussi, F ;
Ip, WY ;
Chow, SP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (09) :1303-1312
[4]
HASTINGS H, 1993, ORTHOP CLIN N AM, V24, P309
[5]
Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures [J].
Ring, D ;
Jupiter, JB ;
Brennwald, J ;
Buchler, U ;
Hastings, H .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22A (05) :777-784