Intraoperative assessment of tibiofemoral contact stresses in total knee arthroplasty

被引:51
作者
Wallace, AL [1 ]
Harris, ML [1 ]
Walsh, WR [1 ]
Bruce, WJM [1 ]
机构
[1] Prince Wales Hosp, Dept Orthopaed Surg, Sydney, NSW, Australia
关键词
implant; wear; polyethylene; arthroplasty; knee;
D O I
10.1016/S0883-5403(98)90200-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The production of polyethylene wear debris in total knee arthroplasty (TKA) is due to multiple factors. In particular, inadequate implant alignment and high bearing surface contact stresses are associated with polyethylene failure. Optimal implant placement and soft tissue balancing may contribute to reducing wear and the production of polyethylene particles. We present a case in which a quantitative technique was used to measure tibiofemoral contact stresses during implantation of a total knee prosthesis in vivo. In a knee with preoperative varus and fixed flexion deformity, medial compartment contact stresses after initial resection were reduced from 14.3 MPa to 11.3 MPa in neutral alignment by additional bone resection. Posterior cruciate release was required to reduce contact stresses further and to provide satisfactory balance between medial and lateral compartments, as determined by the operating surgeon, and was confirmed by the measurement system (3.8 MPa medially; 3.0 MPa laterally). This technique has potential to fine-time implant positioning and ligament balancing during TKA.
引用
收藏
页码:923 / 927
页数:5
相关论文
共 13 条
[1]
THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[2]
COLLIER JP, 1991, CLIN ORTHOP RELAT R, P232
[3]
HSU HP, 1989, CLIN ORTHOP RELAT R, P135
[4]
KILGUS DJ, 1991, CLIN ORTHOP RELAT R, P223
[5]
INFLUENCE OF POSITIONING OF PROSTHESIS IN TOTAL KNEE REPLACEMENT [J].
LOTKE, PA ;
ECKER, ML .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (01) :77-79
[6]
Matsuda S., 1995, T ORTHOP RES SOC, V20, P743
[7]
MCNAMARA JL, 1994, CLIN ORTHOP RELAT R, P104
[8]
RITTER MA, 1994, CLIN ORTHOP RELAT R, P153
[9]
TIBIOFEMORAL CONTACT STRESS AND STRESS-DISTRIBUTION EVALUATION OF TOTAL KNEE ARTHROPLASTIES [J].
SZIVEK, JA ;
CUTIGNOLA, L ;
VOLZ, RG .
JOURNAL OF ARTHROPLASTY, 1995, 10 (04) :480-491
[10]
Soft-tissue balancing with pressure distribution during total knee arthroplasty [J].
Takahashi, T ;
Wada, Y ;
Yamamoto, H .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :235-239