An FEM approach for the characterization of the RF field homogeneity at high field

被引:16
作者
Guclu, C
Kashmar, G
Hacinliyan, A
Nalcioglu, O
机构
[1] UNIV CALIF IRVINE,DEPT RADIOL SCI,DIV PHYS & ENGN,IRVINE,CA 92697
[2] VET ADM MED CTR,LONG BEACH,CA 90822
[3] BOGAZICI UNIV,DEPT PHYS,ISTANBUL,TURKEY
关键词
magnetic resonance imaging; radiofrequency resonators; finite element method;
D O I
10.1002/mrm.1910370112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High field magnetic resonance offers new opportunities because of its high SNR and better spectral resolution for MRI and MRS, However, new problems also emerge at high field, As the field strength increases, the wavelength in the tissue becomes shorter and comparable with the body dimensions. This perturbs the field and also causes standing waves within the patient as a result of the impedance mismatching at the tissue interfaces, Due to the complexity of the boundary conditions and the solution of Maxwell's equations, an exact analytical calculation for a loaded RF resonator has not been possible. In this paper, we present a birdcage coil simulation study based on a 3D finite element method (FEM) model for the characterization of the field within the tissue. First, the accuracy of the FEM solutions is validated by the 2D analytical solutions at 64 and 223 MHz. In these solutions, the frequency dependence of the conductivity and permittivity is also taken into account. Then, a more realistic 3D model is studied, The results are compared with the experimental measurements, It is shown that the 3D model makes it possible to explore the effects of the end rings in the presence of a tissue sample inside the coil.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 22 条
[1]  
[Anonymous], 1993, What every engineer should know about finite element analysis
[2]  
BRAUER JR, 1993, MSC EMAS USERS MANUA
[3]  
DUCK FA, 1990, PHYSICAL PROPERTIES
[4]  
FOO T, P SMRM 9 ANN M NEW 1, P510
[5]   AN ANALYTICAL MODEL FOR THE DESIGN OF RF RESONATORS FOR MR BODY IMAGING [J].
FOO, TKF ;
HAYES, CE ;
KANG, YW .
MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (02) :165-177
[6]   REDUCTION OF RF PENETRATION EFFECTS IN HIGH-FIELD IMAGING [J].
FOO, TKF ;
HAYES, CE ;
KANG, YW .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :287-301
[7]   AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T [J].
HAYES, CE ;
EDELSTEIN, WA ;
SCHENCK, JF ;
MUELLER, OM ;
EASH, M .
JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) :622-628
[8]  
Hayes CE, 1987, Patent No. [US patent 4,694,255. 1987, 4694255]
[9]   ELECTRIC-FIELD MEASUREMENTS IN CYLINDRICAL IMAGING COILS [J].
JOSEPH, PM ;
SAADIELMANDJRA, M .
JOURNAL OF MAGNETIC RESONANCE, 1987, 75 (02) :199-212
[10]  
KRIEZIS BE, 1992, P IEEE, V10, P1559