Microsensor based on NASICON for the analysis of Na+ in the gingival fluid

被引:4
作者
Caravel, G [1 ]
Poignet, N [1 ]
Siebert, E [1 ]
Fabry, P [1 ]
机构
[1] Ecole Natl Super Electrochim & Electromet Grenoble, Lab Electrochim & Physicochime Mat & Interfaces, F-38402 St Martin Dheres, France
关键词
NASICON; gingival fluid; Na+ analysis; ion-selective electrode;
D O I
10.1016/S0925-4005(01)00604-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized electrochemical sensor for in vivo determination of Na+ in the gingival fluid is described. The device includes a NASICON type ceramic as the ion-sensitive membrane and a polyethylene-oxide-based polymer as the internal reference system. The device was successfully used for the direct determination of Na+ activity in gingival fluid. The response time was as short as 10 s. Measurements were performed with an external miniaturized calomel electrode located in the vestibular cavity. Some tests were also performed with an integrated Ag-AgCl electrode. The recordings clearly demonstrate that such a Na+ probe can be used to make in vivo diagnosis. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:506 / 511
页数:6
相关论文
共 12 条
[1]   A NEW DOUBLE-JET CELL FOR FAST ION-SENSITIVE ELECTRODES [J].
ATTARI, M ;
FABRY, P ;
MALLIE, H ;
QUEZEL, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 15 (1-3) :173-178
[2]  
BUCK RP, 1982, ION SEL ELECTRODE RE, V4, P3
[3]   NASICON, AN IONIC CONDUCTOR FOR SOLID-STATE NA+-SELECTIVE ELECTRODE [J].
FABRY, P ;
GROS, JP ;
MILLIONBRODAZ, JF ;
KLEITZ, M .
SENSORS AND ACTUATORS, 1988, 15 (01) :33-49
[4]   POLYMER ELECTROLYTE AS INTERNAL IONIC BRIDGE FOR ION SOLID-STATE SENSORS [J].
FABRY, P ;
MONTEROOCAMPO, C ;
ARMAND, M .
SENSORS AND ACTUATORS, 1988, 15 (01) :1-9
[5]   MEASUREMENT OF GINGIVAL CREVICULAR FLUID CONDUCTIVITY, INVIVO [J].
FERRIS, G ;
GROW, TE ;
LOW, SB ;
FERRIS, RT .
JOURNAL OF PERIODONTOLOGY, 1987, 58 (01) :46-50
[6]   Kinetics of sodium and silver exchange on a PEO(x)-NaI-(AgI)(0.25) based internal reference system [J].
Gondran, C ;
Albert, F ;
Siebert, E .
SOLID STATE IONICS, 1996, 84 (1-2) :131-138
[7]   ELECTROCHEMICAL STABILITY OF BETA-ALUMINA AND NASICON - ESR CHARACTERIZATION OF LARGE METALLIC SODIUM PRECIPITATES [J].
GOURIER, D ;
BARRET, JP ;
VIVIEN, D .
SOLID STATE IONICS, 1989, 31 (04) :301-311
[8]   QUANTITATIVE ANALYSIS OF SODIUM, POTASSIUM AND CALCIUM IN GINGIVAL FLUID FROM GINGIVA IN VARYING DEGREES OF INFLAMMATION [J].
KASLICK, RS ;
CHASENS, AI ;
MANDEL, ID ;
WEINSTEIN, D ;
WALDMAN, R ;
PLUHAR, T ;
LAZZARA, R .
JOURNAL OF PERIODONTOLOGY, 1970, 41 (02) :93-+
[9]   Optimization of NASICON composition for Na+ recognition [J].
Khireddine, H ;
Fabry, P ;
Caneiro, A ;
Bochu, B .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 40 (2-3) :223-230
[10]  
POIGNET N, 1997, THESIS I NATL POLYTE