Comparison of accelerometers with oxygen consumption in older adults during exercise

被引:70
作者
Fehling, PC [1 ]
Smith, DL
Warner, SE
Dalsky, GP
机构
[1] Skidmore Coll, Dept Exercise Sci & Dance, Saratoga Springs, NY 12866 USA
[2] Univ Connecticut, Ctr Hlth, Farmington, CT 06030 USA
关键词
physical activity; caloric expenditure; energy expenditure;
D O I
10.1097/00005768-199901000-00026
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: The purpose of this study was to compare two commercially available accelerometers with indirect calorimetry in a group of older adults (x +/- SD; 70.6 +/- 3.7 yr; N = 86, 44 males and 42 females). Methods: The accelerometers (Caltrac and Tritrac, Hemokinetics, Madison, WI) were worn while performing three submaximal, discontinuous (5 min exercise, 2 min recovery), progressive levels of treadmill walking and bench stepping. The treadmill exercise averaged 3.4 mph, at 0.4% grade, 3.0% grade, and 5.1% grade, while the stepping work rates (24 steps.min(-1)) were performed on 15.2-, 20.3-, and 25.4-cm steps. Estimated energy expenditure (EE) from the two accelerometers was compared with EE as measured by indirect calorimetry. Results: The Caltrac significantly (P < 0.05) overestimated EE at the three treadmill work rates (10-52% difference) and underestimated EE at the three stepping work rates (-19% to -28% difference). When comparing the changes in EE between work rates one, two and three, the Caltrac was not sensitive to the changes (increase in EE) that occurred during graded treadmill walking but did detect some changes in the stepping exercise. The Tritrac significantly (P < 0.05) underestimated EE for the three work rates of both the treadmill and stepping exercise when compared with indirect calorimetry but did detect differences in EE among work rates during stepping exercise (P < 0.05). Conclusions: These data indicate that the magnitude of the differences between measured and estimated EE is affected by exercise mode and intensity and that caution is warranted when using the acceleromerers in an attempt to quantify EE in older adults.
引用
收藏
页码:171 / 175
页数:5
相关论文
共 23 条
[1]  
ASTRAND PO, 1986, TXB WORK PHYSL PHYSL, P544
[2]   CALORIMETRIC VALIDATION OF THE CALTRAC ACCELEROMETER DURING LEVEL WALKING [J].
BALOGUN, JA ;
MARTIN, DA ;
CLENDENIN, MA .
PHYSICAL THERAPY, 1989, 69 (06) :501-509
[3]  
BALOGUN JA, 1988, PHYS THER, V68, P1500
[4]   Accuracy of five electronic pedometers for measuring distance walked [J].
Bassett, DR ;
Ainsworth, BE ;
Leggett, SR ;
Mathien, CA ;
Main, JA ;
Hunter, DC ;
Duncan, GE .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (08) :1071-1077
[5]  
BOUTEN CV, 1994, MED SCI SPORT EXER, V26, P1516
[6]  
BRAY MS, 1994, MED SCI SPORT EXER, V26, P1524
[7]  
Haskel WL, 1996, RES Q EXERCISE SPORT, V67, P37
[8]  
HAYMES EM, 1993, MED SCI SPORT EXER, V25, P1365
[9]  
MELANSON EL, 1995, MED SCI SPORT EXER, V27, P934
[10]  
MONTOYE HJ, 1983, MED SCI SPORT EXER, V15, P403