Single-shot T1- and T2-weighted magnetic resonance imaging of the heart with black blood: Preliminary experience

被引:39
作者
Stehling, MK
Holzknecht, NG
Laub, G
Bohm, D
vonSmekal, A
Reiser, M
机构
[1] UNIV MUNICH,KLINIKUM GROSSHADERN,DEPT DIAGNOST RADIOL,D-81366 MUNICH,GERMANY
[2] UNIV MUNICH,DEPT CARDIAC SURG,D-81366 MUNICH,GERMANY
[3] SIEMENS MED ENGN GRP,ERLANGEN,GERMANY
来源
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE | 1996年 / 4卷 / 3-4期
关键词
magnetic resonance; heart; rapid imaging; fast spin-echo;
D O I
10.1007/BF01772011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To implement and evaluate two robust methods for T1- and T2-weighted snapshot imaging of the heart with data acquisition within a single heart beat and suppression of blood signal. Methods: Both T1- and T2-weighted diastolic images of the heart can be obtained with half Fourier single-shot turbo spin echo (HASTE) and turbo fast low-angle shot (turboFLASH) sequences, respectively, in less than 350 ms. Signal from flowing blood in the ventricles and large vessels can be suppressed by a preceding inversion recovery preparing pulse pair (PRESTO). Fifteen volunteers and five patients have been evaluated quantitatively for signal-to-noise ratio (SNR) contrast-to-noise ratio (CNR) and flow void and qualitatively for image quality artifacts, and black-blood effect. Results: Both PRESTO-HASTE and PRESTO-turboFLASH achieved consistently good image quality and blood signal suppression. Ln contrast to gradient-echo (GRE) echo-planar imaging techniques, (EPI) HASTE and turboFLASH are much less sensitive to local susceptibility differences in the thorax, resulting in a more robust imaging technique without the need for time-consuming system tuning. Compared to standard spin-echo sequences with cardiac triggering, HASTE and turboFLASH have significantly shorter image acquisition times and are not vulnerable to respiratory motion artifacts. Conclusion: PRESTO-HASTE and PRESTO-turboFLASH constitute suitable methods for fast and high-quality cardiac magnetic resonance imaging (MRI).
引用
收藏
页码:231 / 240
页数:10
相关论文
共 15 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]   NORMAL HEART - EVALUATION WITH ECHO-PLANAR MR-IMAGING [J].
DAVIS, CP ;
MCKINNON, GC ;
DEBATIN, JF ;
WETTER, D ;
EICHENBERGER, AC ;
DUEWELL, S ;
VONSCHULTHESS, GK .
RADIOLOGY, 1994, 191 (03) :691-696
[3]   FAST SELECTIVE BLACK BLOOD MR IMAGING [J].
EDELMAN, RR ;
CHIEN, D ;
KIM, D .
RADIOLOGY, 1991, 181 (03) :655-660
[4]   INVERSION RECOVERY SNAPSHOT FLASH MR IMAGING [J].
HAASE, A ;
MATTHAEI, D ;
BARTKOWSKI, R ;
DUHMKE, E ;
LEIBFRITZ, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (06) :1036-1040
[5]   ZEUGMATOGRAPHY: A CRITICISM OF THE CONCEPT OF A SELECTIVE PULSE IN THE PRESENCE OF A FIELD GRADIENT [J].
HOULT, DI .
JOURNAL OF MAGNETIC RESONANCE, 1977, 26 (01) :165-167
[6]  
LAUB G, 1995, P SOC MAGN RES MED E, P246
[7]  
Listerud J, 1992, Magn Reson Q, V8, P199
[8]   BIOLOGICAL AND MEDICAL IMAGING BY NMR [J].
MANSFIELD, P ;
PYKETT, IL .
JOURNAL OF MAGNETIC RESONANCE, 1978, 29 (02) :355-373
[9]   SNAPSHOT IMAGING AT 0.5-T USING ECHO-PLANAR TECHNIQUES [J].
ORDIDGE, RJ ;
HOWSEMAN, A ;
COXON, R ;
TURNER, R ;
CHAPMAN, B ;
GLOVER, P ;
STEHLING, M ;
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (02) :227-240
[10]   THE NMR PHASED-ARRAY [J].
ROEMER, PB ;
EDELSTEIN, WA ;
HAYES, CE ;
SOUZA, SP ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :192-225