Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing

被引:318
作者
Ge, Lei [1 ]
Yan, Jixian [1 ]
Song, Xianrang [2 ]
Yan, Mei [1 ]
Ge, Shenguang [3 ]
Yu, Jinghua [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
[2] Shandong Tumor Hosp, Canc Res Ctr, Jinan 250117, Peoples R China
[3] Univ Jinan, Shandong Prov Key Lab Fluorine Chem & Chem Mat, Jinan 250022, Peoples R China
关键词
Electrochemiluminescence immunoassay; Lab on paper; Screen-printed electrode; Biomarker; Point-of-care testing; MICROFLUIDIC DEVICES; CHEMILUMINESCENCE DETECTION; CAMERA PHONES; TUMOR-MARKERS; ON-PAPER; LOW-COST; ELECTRONICS; TIME; FLOW; WAX;
D O I
10.1016/j.biomaterials.2011.10.065
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work, electrochemiluminescence (ECL) immunoassay was introduced into the recently proposed microfluidic paper-based analytical device (mu PADs) based on directly screen-printed electrodes on paper for the very first time. The screen-printed paper-electrodes will be more important for further development of this paper-based ECL device in simple, low-cost and disposable application than commercialized ones. To further perform high-performance, high-throughput, simple and inexpensive ECL immunoassay on mu PAD for point-of-care testing, a wax-patterned three-dimensional (3D) paper-based ECL device was demonstrated for the very first time. In this 3D paper-based ECL device, eight carbon working electrodes including their conductive pads were screen-printed on a piece of square paper and shared the same Ag/AgCl reference and carbon counter electrodes on another piece of square paper after stacking. Using typical tris-(bipyridine)-ruthenium (II) - tri-n-propylamine ECL system, the application test of this 3D paper-based ECL device was performed through the diagnosis of four tumor markers in real clinical serum samples. With the aid of a facile device-holder and a section-switch assembled on the analyzer, eight working electrodes were sequentially placed into the circuit to trigger the ECL reaction in the sweeping range from 0.5 to 1.1 V at room temperature. In addition, this 3D paper-based ECL device can be easily integrated and combined with the recently emerging paper electronics to further develop simple, sensitive, low-cost, disposable and portable mu RAD for point-of-care testing, public health and environmental monitoring in remote regions, developing or developed countries. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1024 / 1031
页数:8
相关论文
共 47 条
  • [1] Inkjet-printed microfluidic multianalyte chemical sensing paper
    Abe, Koji
    Suzuki, Koji
    Citterio, Daniel
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (18) : 6928 - 6934
  • [2] [Anonymous], MODERN CLIN IMMUNOAS
  • [3] Lab-on-Paper with Dual Electrochemical/Colorimetric Detection for Simultaneous Determination of Gold and Iron
    Apilux, Amara
    Dungchai, Wijitar
    Siangproh, Weena
    Praphairaksit, Narong
    Henry, Charles S.
    Chailapakul, Orawon
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (05) : 1727 - 1732
  • [4] Low-cost printing of poly(dimethylsiloxane) barriers to define microchannels in paper
    Bruzewicz, Derek A.
    Reches, Meital
    Whitesides, George M.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (09) : 3387 - 3392
  • [5] Paper Microzone Plates
    Carrilho, Emanuel
    Phillips, Scott T.
    Vella, Sarah J.
    Martinez, Andres W.
    Whitesides, George M.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (15) : 5990 - 5998
  • [6] Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
    Carrilho, Emanuel
    Martinez, Andres W.
    Whitesides, George M.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (16) : 7091 - 7095
  • [7] Paper-Based ELISA
    Cheng, Chao-Min
    Martinez, Andres W.
    Gong, Jinlong
    Mace, Charles R.
    Phillips, Scott T.
    Carrilho, Emanuel
    Mirica, Katherine A.
    Whitesides, George M.
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (28) : 4771 - 4774
  • [8] Chitnis G, 2011, LAB CHIP, V11, P1161, DOI [10.1039/c0lc00512f, 10.1039/c01c00512f]
  • [9] SEMIQUANTITATIVE SPECIFIC TEST PAPER FOR GLUCOSE IN URINE
    COMER, JP
    [J]. ANALYTICAL CHEMISTRY, 1956, 28 (11) : 1748 - 1750
  • [10] Electrogenerated Chemiluminescence Detection in Paper-Based Microfluidic Sensors
    Delaney, Jacqui L.
    Hogan, Conor F.
    Tian, Junfei
    Shen, Wei
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (04) : 1300 - 1306