Measurement of total serum testosterone in adult men:: Comparison of current laboratory methods versus liquid chromatography-tandem mass spectrometry

被引:447
作者
Wang, C
Catlin, DH
Demers, LM
Starcevic, B
Swerdloff, RS
机构
[1] Harbor UCLA Med Ctr, Dept Med, Div Endocrinol, Torrance, CA 90502 USA
[2] Res & Educ Inst, Torrance, CA 90502 USA
[3] Univ Calif Los Angeles, Olymp Analyt Lab, Los Angeles, CA 90025 USA
[4] Penn State Univ, HS Hershey Med Ctr, Coll Med, Dept Pathol & Med, Hershey, PA 17033 USA
关键词
D O I
10.1210/jc.2003-031287
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The diagnosis of male hypogonadism requires the demonstration of a low serum testosterone (T) level. We examined serum T levels in pedigreed samples taken from 62 eugonadal and 60 hypogonadal males by four commonly used automated immunoassay instruments (Roche Elecsys, Bayer Centaur, Ortho Vitros ECi and DPC Immulite 2000) and two manual immunoassay methods (DPC-RIA, a coated tube commercial kit, and HUMC-RIA, a research laboratory assay) and compared results with measurements performed by liquid chromatography-tandem mass spectrometry (LC-MSMS). Deming's regression analyses comparing each of the test results with LC-MSMS showed slopes that were between 0.881 and 1.217. The interclass correlation coefficients were between 0.92 and 0.97 for all methods. Compared with the serum T concentrations measured by LC-MSMS, the DPC Immulite results were biased toward lower values (mean difference, -90+/-9 ng/dl) whereas the Bayer Centaur data were biased toward higher values (mean difference, +99+/-11 ng/dl) over a wide range of serum T levels. At low serum T concentrations (<100 ng/dl or 3.47 nmol/liter), HUMC-RIA overestimated serum T, Ortho Vitros ECi underestimated the serum T concentration, whereas the other two methods (DPC-RIA and Roche Elecsys) showed differences in both directions compared with LC-MSMS. Over 60% of the samples (with T levels within the adult male range) measured by most automated and manual methods were within +/- 20% of those reported by LC-MSMS. These immunoassays are capable of distinguishing eugonadal from hypogonadal males if adult male reference ranges have been established in each individual laboratory. The lack of precision and accuracy, together with bias of the immunoassay methods at low serum T concentrations, suggests that the current methods cannot be used to accurately measure T in females or serum from prepubertal subjects.
引用
收藏
页码:534 / 543
页数:10
相关论文
共 28 条
[1]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
CHEN JC, 1971, CLIN CHEM, V17, P581
[4]  
Dewitte K, 2002, CLIN CHEM, V48, P799
[5]   Measurement of steroid sex hormones in serum: a comparison of radioimmunoassay and mass spectrometry [J].
Dorgan, JF ;
Fears, TR ;
McMahon, RP ;
Friedman, LA ;
Patterson, BH ;
Greenhut, SF .
STEROIDS, 2002, 67 (3-4) :151-158
[6]   Quantitation of anabolic hormones and their metabolites in bovine serum and urine by liquid chromatography-tandem mass spectrometry [J].
Draisci, R ;
Palleschi, L ;
Ferretti, E ;
Lucentini, L ;
Cammarata, P .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :511-522
[7]  
DUDLEY RA, 1985, CLIN CHEM, V31, P1264
[8]   RADIOIMMUNOASSAY OF PLASMA TESTOSTERONE [J].
DUFAU, ML ;
RYAN, D ;
TSURUHAR.T ;
CATT, KJ .
CLINICA CHIMICA ACTA, 1972, 37 (NMAR) :109-+
[9]   A RADIOIMMUNOASSAY FOR PLASMA TESTOSTERONE [J].
FURUYAMA, S ;
MAYES, DM ;
NUGENT, CA .
STEROIDS, 1970, 16 (04) :415-&
[10]   BIOMEDICAL AND BIOCHEMICAL APPLICATIONS OF LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
GELPI, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :59-80