Evaluation of metal ion release and corrosion resistance of ZrO2 thin coatings on the dental Co-Cr alloys

被引:33
作者
Hsu, HC [1 ]
Yen, SK [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Mat Engn, Taichung 40227, Taiwan
关键词
D O I
10.1016/S0109-5641(99)00002-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The aim of this study was to determine if electrolytic ZrO2 thin coatings increased the corrosion resistance and decreased the metal ion release of dental cobalt-chromium alloys. Methods. Dental Co-Cr alloys were electrolytically deposited with ZrO2 ceramic coatings using a 0.0625 M ZrO(NO3)(2) solution, at various potentials, for 500 s. The electrolytic ZrO2 gel-coated specimens were annealed at 723 K for 1 h in air. Scanning electron microscopy (SEM) was used to observe the morphology of the ZrO2 ceramic coatings on Co-Cr alloys. A dynamic polarization test was used to compare the corrosion resistance of the ZrO2 coated and uncoated Co-Cr alloys in artificial saliva. Metal ion concentrations were determined with graphite furnace atomic absorption spectroscopy (AAS). Results. The SEM micrographs showed that the Co-Cr alloy can be coated with zirconia oxide at -0.7 V more homogeneously and more completely than at -1.5 V. The polarization curves indicated that the ZrO2 coating on Co-Cr alloys annealed at 723 K for 1 h in air exhibited better corrosion resistance in artificial saliva. The results of the AASs showed that the ZrO2-coated Co-Cr alloys decreased chromium ion release levels, as compared with the uncoated Co-Cr alloys. The scratch test indicated a good bond strength between the ZrO2 and Co-Cr alloy Significance. The electrolytically deposited ZrO2 coatings on Co-Cr alloys may improve the corrosion resistance and decrease the release of metal ions. It is suggested that the electrolytic ZrO2 coating method could have a widespread application in dentistry in the future. (C) 1999 Academy of Dental Materials. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:339 / 346
页数:8
相关论文
共 27 条
[1]   SHEAR TEST FOR MEASURING BONDING IN CAST GOLD ALLOY-PORCELAIN COMPOSITES [J].
ANTHONY, DH ;
BURNETT, AP ;
SMITH, DL ;
BROOKS, MS .
JOURNAL OF DENTAL RESEARCH, 1970, 49 (01) :27-&
[2]   COMPARATIVE-EVALUATION OF CERAMIC-METAL BOND TESTS USING FINITE-ELEMENT STRESS-ANALYSIS [J].
ANUSAVICE, KJ ;
DEHOFF, PH ;
FAIRHURST, CW .
JOURNAL OF DENTAL RESEARCH, 1980, 59 (03) :608-613
[3]   BONDING MECHANISM EVIDENCE IN A CERAMIC - NONPRECIOUS ALLOY SYSTEM [J].
ANUSAVICE, KJ ;
RINGLE, RD ;
FAIRHURST, CW .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1977, 11 (05) :701-709
[4]   EFFECTS OF DENTAL ROOT POSTS ON HUMAN GINGIVAL FIBROBLASTS INVITRO [J].
ARVIDSON, K ;
COTTLERFOX, M ;
FRIBERG, U .
JOURNAL OF DENTAL RESEARCH, 1980, 59 (03) :651-656
[5]  
BETTS B, 1990, CLIN ORTHOP RELAT R, V272, P75
[6]  
Bouchard PR, 1996, J BIOMED MATER RES, V32, P37, DOI 10.1002/(SICI)1097-4636(199609)32:1<37::AID-JBM5>3.0.CO
[7]  
2-Q
[8]   INVITRO AND INVIVO METAL-ION RELEASE [J].
BROWN, SA ;
FARNSWORTH, LJ ;
MERRITT, K ;
CROWE, TD .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (04) :321-338
[9]   THE ADVANTAGES OF COATED TITANIUM IMPLANTS PREPARED BY RADIOFREQUENCY SPUTTERING FROM HYDROXYAPATITE [J].
COOLEY, DR ;
VANDELLEN, AF ;
BURGESS, JO ;
WINDELER, AS .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (01) :93-100
[10]   WEAR ANALYSIS OF RETRIEVED ALUMINA HEADS AND SOCKETS OF HIP PROSTHESES [J].
DORLOT, JM ;
CHRISTEL, P ;
MEUNIER, A .