Impacts of air bleeding on membrane degradation in polymer electrolyte fuel cells

被引:53
作者
Inaba, Minoru [1 ]
Sugishita, Masashi [1 ]
Wada, Junpei [1 ]
Matsuzawa, Koichi [1 ]
Yamada, Hirohisa [1 ]
Tasaka, Akimasa [1 ]
机构
[1] Doshisha Univ, Fac Engn, Dept Mol Sci & Technol, Kyoto 6100321, Japan
关键词
polymer electrolyte fuel cells; Pt-Ru/C anode catalyst; air bleeding; membrane degradation; hydrogen peroxide;
D O I
10.1016/j.jpowsour.2007.08.040
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A long-term accelerated test (4600 h) of a 25 cm(2) single cell with excess air bleeding (5%) was carried out to investigate the effects of air bleeding on membrane degradation in polymer electrolyte fuel cells. The rate of membrane degradation was negligibly low (fluoride-ion release rate= 1.3 x 10(-10) mol cm(-2) h(-1) in average) up to 2000 h. However, membrane degradation rate was gradually increased after 2000 h. The CO tolerance of the anode gradually dropped, which indicated that the anode catalyst was deteriorated during the test. The results of the rotating ring-disk electrode measurements revealed that deterioration of Pt-Ru/C catalyst by potential cycling greatly enhances H2O2 formation in oxygen reduction reaction in the anode potential range (similar to 0 V). Furthermore, membrane degradation rate of the MEA increased after the anode catalyst was forced to be deteriorated by potential cycling. It was concluded that excess air bleeding deteriorated the anode catalyst, which greatly enhanced H2O2 formation upon air bleeding and resulted in the increased membrane degradation rate after 2000 h. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:699 / 705
页数:7
相关论文
共 22 条
[1]  
Bard A. J., 2000, ELECTROCHEMICAL METH, P331
[2]   Advanced materials for improved PEMFC performance and life [J].
Curtin, DE ;
Lousenberg, RD ;
Henry, TJ ;
Tangeman, PC ;
Tisack, ME .
JOURNAL OF POWER SOURCES, 2004, 131 (1-2) :41-48
[3]  
GASTEIGER H, 2003, HDB FUEL CELLS, V3, P595
[4]   A NEW APPROACH TO THE PROBLEM OF CARBON-MONOXIDE POISONING IN FUEL-CELLS OPERATING AT LOW-TEMPERATURES [J].
GOTTESFELD, S ;
PAFFORD, J .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (10) :2651-2652
[5]   Determination of the platinum and ruthenium surface areas in platinum-ruthenium alloy electrocatalysts by underpotential deposition of copper. I. Unsupported catalysts [J].
Green, CL ;
Kucernak, A .
JOURNAL OF PHYSICAL CHEMISTRY B, 2002, 106 (05) :1036-1047
[6]   Effect of loading level in platinum-dispersed carbon black electrocatalysts on oxygen reduction activity evaluated by rotating disk electrode [J].
Higuchi, E ;
Uchida, H ;
Watanabe, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 583 (01) :69-76
[7]   Effect of agglomeration of Pt/C catalyst on hydrogen peroxide formation [J].
Inaba, M ;
Yamada, H ;
Tokunaga, J ;
Tasaka, A .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 2004, 7 (12) :A474-A476
[8]  
INABA M, 2007, NENRYO DENCHI, V6, P16
[9]   Controlled growth and shape formation of platinum nanoparticles and their electrochemical properties [J].
Inaba, Minoru ;
Ando, Miwa ;
Hatanaka, Aoi ;
Nomoto, Akihiro ;
Matsuzawa, Koichi ;
Tasaka, Akimasa ;
Kinumoto, Taro ;
Iriyama, Yasutoshi ;
Ogumi, Zempachi .
ELECTROCHIMICA ACTA, 2006, 52 (04) :1632-1638
[10]   Membrane degradation in polymer electrolyte fuel cells under low humidification conditions [J].
Inaba, Minoru ;
Yamada, Hirohisa ;
Umebayashi, Ryota ;
Sugishita, Masashi ;
Tasaka, Akimasa .
ELECTROCHEMISTRY, 2007, 75 (02) :207-212