Determination and correction of analytical biases and study on chemical mechanisms in the analysis of Cr(VI) in soil samples using EPA protocols

被引:59
作者
Huo, DW
Lu, YS
Kingston, HM [1 ]
机构
[1] Duquesne Univ, Dept Chem & Biochem, Pittsburgh, PA 15282 USA
[2] Duquesne Univ, Environm Sci Program, Pittsburgh, PA 15282 USA
关键词
D O I
10.1021/es971029e
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
EPA Methods 3060A (alkaline extraction) and 7196A (colorimetric measurement) currently constitute a pair of protocols for the measurement of Cr(VI) in environmental soil samples in EPA RCRA SW-846 Update ill. To identify the sources of possible biases, we applied the newly developed Speciated Isotope Dilution Mass Spectrometry (SIDMS) as an alternative detection method to Method 7196A. SIDMS is capable of correcting for species transformation, while Method 7196A is nor. In Method 3060A, soluble Cr(III) could be oxidized during extraction, resulting in positive errors of Cr(VI); Cr(VI) could be lost or reduced during neutralization, leading to negative errors of Cr(VI). When sand and soil extracts were analyzed, low recoveries were obtained with Method 7196A. However, SIDMS achieved approximately 100% recoveries. The influence of some soil matrix components on the detection of Cr(VI) using Method 7196A has been evaluated. As expected, reducing agents could cause low recoveries of Cr(VI). Surprisingly, we found that strong oxidizing agents could also result in low recoveries. We identify these method biases and discuss the mechanisms in this paper.
引用
收藏
页码:3418 / 3423
页数:6
相关论文
共 27 条
[1]   Flow dissolution of 1,5-diphenylcarbazide for the determination of chromium(VI) [J].
Andrade, FJ ;
Tudino, MB ;
Troccoli, OE .
ANALYST, 1996, 121 (05) :613-616
[2]  
[Anonymous], [No title captured]
[3]  
BARTLETT RJ, 1988, CHROMIUM NATURAL HUM, V20, P267
[4]  
Burrows D., 1983, CHROMIUM METABOLISM
[5]  
Darrin M., 1956, CHROMIUM, V1, P251
[6]  
DEAN JA, 1985, LNAGES HDB CHEM
[7]  
*DION CORP, 1990, 26 DION CORP, P7
[8]  
*HACH CO, 1992, WAT AN HDB, P763
[10]  
HUO D, 1996, 1996 PITTSB C CHIC I, P887