Nonporous expanded polytetrafluoroethylene grafts reduces graft neointimal hyperplasia in dog and baboon models

被引:22
作者
Lumsden, AB
Chen, CY
Coyle, KA
Ofenloch, JC
Wang, JH
Yasuda, HK
Hanson, SR
机构
[1] EMORY UNIV,SCH MED,DEPT MED,DIV HEMATOL ONCOL,ATLANTA,GA 30322
[2] EMORY UNIV,YERKES REG PRIMATE RES CTR,ATLANTA,GA 30322
[3] UNIV MISSOURI,DEPT CHEM ENGN,COLUMBIA,MO 65211
[4] UNIV MISSOURI,CTR SURFACE SCI & PLASMA TECHNOL,COLUMBIA,MO 65211
[5] EMORY UNIV,SCH MED,DEPT SURG,ATLANTA,GA 30322
关键词
D O I
10.1016/S0741-5214(96)70019-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Neointimal hyperplasia frequently develops after placement of prosthetic vascular grafts and is a major cause of graft failure. This study was an attempt to prevent vascular lesion formation by coating the graft luminal surface with a thin layer of nonporous silicone polymer, and subsequently with an ultrathin layer of vapor phase (plasma gas)-deposited fluoropolymer, thereby providing a smooth and chemically uniform surface that was postulated to limit pannus tissue ingrowth across the graft anastomoses. Methods: Bilateral femoral arteriovenous (AV) conduits were constructed in four dogs using expanded polytetrafluoroethylene graft materials (ePTFE; 6-mm inside diameter, 2.5-cm long). In each animal, one femoral AV shunt was constructed from a graft whose luminal surface was entirely coated with polymer. On the contralateral side, an uncoated graft served as a control. Bilateral aortoiliac grafts were placed in three baboons using 5-cm segments of ePTFE (4-mm inside diameter). One end (1 cm) of each graft had been coated with polymer In each animal, the coated end of one graft was placed proximally and the coated end of the second graft was placed distally in the contralateral vessels. Results: All grafts were patent at 30 days. In the dog model, there was a significant reduction in graft neointimal area at the venous anastomoses for the coated grafts compared with the uncoated grafts (0.03 +/- 0.02 mm(2) and 1.11 +/- 0.54 mm2, respectively; p < 0.05). In the baboon model, the silicone coating significantly reduced the graft neointimal thickness (0.003 +/- 0.003 mm vs 0.21 +/- 0.05 mm; P < 0.05) and neointimal area (0.05 +/- 0.08 mm2 vs 0.82 +/- 0.58 mm2; p < 0.05). Conclusions: These data demonstrate that healing of ePTFE grafts can be effectively modified by altering the physical properties of the graft surface. Neointimal hyperplasia within ePTFE grafts is significantly reduced by the local application of a fluorocarbon-coated, silicone-based polymer. The resulting graft now surface effectively prevents tissue ingrowth from the adjacent native vessel, thereby preserving the anastomosis luminal area. This approach could represent a new strategy for limiting graft surface anastomotic neointimal hyperplasia.
引用
收藏
页码:825 / 833
页数:9
相关论文
共 31 条
[1]   HEALING OF ARTERIAL PROSTHESES IN MAN - ITS INCOMPLETENESS [J].
BERGER, K ;
WOOD, SJ ;
SAUVAGE, LR ;
RAO, AM .
ANNALS OF SURGERY, 1972, 175 (01) :118-&
[2]   BOUNDARY-LAYER INFUSION OF HEPARIN PREVENTS THROMBOSIS AND REDUCES NEOINTIMAL HYPERPLASIA IN VENOUS POLYTETRAFLUOROETHYLENE GRAFTS WITHOUT SYSTEMIC ANTICOAGULATION [J].
CHEN, CY ;
HANSON, SR ;
LUMSDEN, AB .
JOURNAL OF VASCULAR SURGERY, 1995, 22 (03) :237-247
[3]   MECHANISMS OF ARTERIAL GRAFT FAILURE .2. CHRONIC ENDOTHELIAL AND SMOOTH-MUSCLE CELL-PROLIFERATION IN HEALING POLYTETRAFLUOROETHYLENE PROSTHESES [J].
CLOWES, AW ;
KIRKMAN, TR ;
CLOWES, MM .
JOURNAL OF VASCULAR SURGERY, 1986, 3 (06) :877-884
[4]  
CLOWES AW, 1985, AM J PATHOL, V118, P43
[5]  
COOLEY DA, 1978, VASCULAR GRAFTS, P197
[6]  
EDWARDS WS, 1978, ARCH SURG-CHICAGO, V113, P1225
[7]  
GARFINKLE AM, 1984, T AM SOC ART INT ORG, V30, P432
[8]   HEALING OF POLYTETRAFLUOROETHYLENE ARTERIAL GRAFTS IS INFLUENCED BY GRAFT POROSITY [J].
GOLDEN, MA ;
HANSON, SR ;
KIRKMAN, TR ;
SCHNEIDER, PA ;
CLOWES, AW .
JOURNAL OF VASCULAR SURGERY, 1990, 11 (06) :838-845
[9]   PLATELET ACCUMULATION ON MATURE DACRON GRAFTS IN MAN [J].
GOLDMAN, M ;
NORCOTT, HC ;
HAWKER, RJ ;
DROLC, Z ;
MCCOLLUM, CN .
BRITISH JOURNAL OF SURGERY, 1982, 69 :S38-S40
[10]  
HANSON SR, 1991, CIRCULATION, V18, P170