Techno-economic valuation and optimization of integrated photovoltaic/wind energy conversion system

被引:115
作者
Kaabeche, Abdelhamid [1 ]
Belhamel, Maiouf [1 ]
Ibtiouen, Rachid [2 ]
机构
[1] Ctr Dev Energies Renouvelables, Algiers, Algeria
[2] Ecole Natl Super Polytech El Harrach, Algiers, Algeria
关键词
Renewable energy system; Unit sizing; Economic viability; Optimization; POWER-GENERATION SYSTEMS; HEAT-PUMP SYSTEM; HYBRID; DESIGN;
D O I
10.1016/j.solener.2011.06.032
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Decentralized electricity generation by renewable energy sources offer greater security of supply for consumers while respecting the environment. But the random nature of these sources requires us to develop sizing rules and use these systems to exploit them. This paper proposes an integrated PV/wind hybrid system optimization model, which utilizes the iterative optimization technique following the Deficiency of Power Supply Probability (DPSP), the Relative Excess Power Generated (REPG), the Total Net Present Cost (TNPC), the Total Annualized Cost (TAC) and Break-Even Distance Analysis (BEDA) for power reliability and system costs. The flow chart of the hybrid optimal sizing model is also illustrated. With this merged model, the optimal size of PV/wind hybrid energy conversion system using battery bank can be performed technically and economically according to the system reliability requirements. Additionally, a sensitivity analysis was carried out in order to appreciate the most important parameters influencing the economic performances of the hybrid system. A case study is conducted to analyze one hybrid project, which is designed to supply small residential household situated in the area of the Center for Renewable Energy Development (CDER) localized in Bouzareah, Algeria (36 degrees 48'N, 3 degrees 1'E, 345 m). (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2407 / 2420
页数:14
相关论文
共 40 条
[1]   Computer-aided design of PV/wind hybrid system [J].
Ai, B ;
Yang, H ;
Shen, H ;
Liao, X .
RENEWABLE ENERGY, 2003, 28 (10) :1491-1512
[2]  
[Anonymous], 1983, INTRO SOLAR RAD
[3]  
[Anonymous], SOLAR ELECT
[4]   Optimal sizing study of hybrid wind/PV/diesel power generation unit [J].
Belfkira, Rachid ;
Zhang, Lu ;
Barakat, Georges .
SOLAR ENERGY, 2011, 85 (01) :100-110
[5]   Design of isolated hybrid systems minimizing costs and pollutant emissions [J].
Bernal-Agustin, Jose L. ;
Dufo-Lopez, Rodolfo ;
Rivas-Ascaso, David M. .
RENEWABLE ENERGY, 2006, 31 (14) :2227-2244
[6]   Methodology for optimally sizing the combination of a battery bank and PV array in a Wind/PV hybrid system [J].
Borowy, BS ;
Salameh, ZM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1996, 11 (02) :367-373
[7]  
BROWN JR, 1985, INTRO LIFE CYCLE COS
[8]   Unit sizing and control of hybrid wind-solar power systems [J].
Chedid, R ;
Rahman, S .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1997, 12 (01) :79-85
[9]  
CHEL A, 2010, ENERGY CONVERSION MA, V5, P1393
[10]   A case study of a typical 2.32 kWP stand-alone photovoltaic (SAPV) in composite climate of New Delhi (India) [J].
Chel, Arvind ;
Tiwari, G. N. .
APPLIED ENERGY, 2011, 88 (04) :1415-1426