Use of a diode laser balloon ablation catheter to generate circumferential pulmonary venous lesions in an open-thoracotomy caprine model

被引:47
作者
Reddy, VY
Houghtaling, C
Fallon, J
Fischer, G
Farr, N
Clarke, J
McIntyre, J
Sinofsky, E
Ruskin, JN
Keane, D
机构
[1] Massachusetts Gen Hosp, Cardiac Arrhythmia Serv, Dept Med, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Mt Sinai Med Ctr, Dept Pathol, New York, NY 10029 USA
[4] CardioFocus Inc, Norton, MA USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2004年 / 27卷 / 01期
关键词
atrial fibrillation; catheter ablation; laser; arrhythmia; reflectance spectroscopy; goat;
D O I
10.1111/j.1540-8159.2004.00385.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Electrical isolation of the pulmonary veins (PVs) can be curative in certain patients with atrial fibrillation. The ability of a diode laser balloon ablation catheter to isolate PVs was assessed in an open-thoracotomy caprine model system. After a median sternotomy, the left atrial appendage was cannulated in 19 goats. A laser balloon catheter was placed at the PV ostia and used to deliver photonic energy to the periostial tissue. The applications were delivered at 3.71 4.5, or 5.4 W/cm for 90-150 seconds. Electrical continuity of the PV with the left atrium was assessed using a multielectrode mapping catheter. After a single application of photonic energy, electrical isolation of the PVs was achieved in (70%) 19/27 PVs. However, the success of electrical PV isolation did not correlate with the dose or duration of the applications. When reflectance spectroscopy was utilized to ensure adequate orientation and contact of the laser balloon catheter with the left atrial myocardium, complete PV isolation was achieved in 5/5 veins at 3.5 W/cm for 120 seconds. Pathological examination revealed no PV stenosis, no pericardial damage, minor lung lesions without pleural perforation, minimal endothelial disruption, and, in the presence of adequate heparinization, no endocardial charring or overlying thrombus. Effective isolation of the PVs can be achieved by delivery of a continuous circular beam of photonic energy to ablate the left atrial - pulmonary venous junction. The use of reflectance spectroscopy to provide real-time monitoring of the blanching effect of balloon-tissue contact optimizes lesion delivery.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 14 条
[1]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[2]   Epidemiology and natural history of atrial fibrillation: Clinical implications [J].
Chugh, SS ;
Blackshear, JL ;
Shen, WK ;
Hammill, SC ;
Gersh, BJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) :371-378
[3]   Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Garrigue, S ;
Takahashi, A ;
Lavergne, T ;
Hocini, M ;
Peng, JT ;
Roudaut, R ;
Clementy, J .
CIRCULATION, 2000, 101 (12) :1409-1417
[4]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[5]   Electrophysiological breakthroughs from the left atrium to the pulmonary veins [J].
Haïssaguerre, M ;
Shah, DC ;
Jaïs, P ;
Hocini, M ;
Yamane, T ;
Deisenhofer, I ;
Chauvin, M ;
Garrigue, S ;
Clémenty, J .
CIRCULATION, 2000, 102 (20) :2463-2465
[6]   A focal source of atrial fibrillation treated by discrete radiofrequency ablation [J].
Jais, P ;
Haissaguerre, M ;
Shah, DC ;
Chouairi, S ;
Gencel, L ;
Hocini, M ;
Clementy, J .
CIRCULATION, 1997, 95 (03) :572-576
[7]   Fiberoptic balloon catheter ablation of pulmonary vein ostia in pigs using photonic energy delivery with diode laser [J].
Lemery, R ;
Veinot, JP ;
Tang, ASL ;
Green, M ;
Farr, N ;
Baxter, L ;
McIntyre, J ;
Sinofsky, E .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (01) :32-36
[8]   Pharmacologic management of atrial fibrillation:: Current therapeutic strategies [J].
Lévy, S .
AMERICAN HEART JOURNAL, 2001, 141 (02) :S15-S21
[9]   Pulmonary vein morphology in patients with paroxysmal atrial fibrillation initiated by ectopic beats originating from the pulmonary veins - Implications for catheter ablation [J].
Lin, WS ;
Prakash, VS ;
Tai, CT ;
Hsieh, MH ;
Tsai, CF ;
Yu, WC ;
Lin, YK ;
Ding, YA ;
Chang, MS ;
Chen, SA .
CIRCULATION, 2000, 101 (11) :1274-1281
[10]   First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation [J].
Natale, A ;
Pisano, E ;
Shewchik, J ;
Bash, D ;
Fanelli, R ;
Potenza, D ;
Santarelli, P ;
Schweikert, R ;
White, R ;
Saliba, W ;
Kanagaratnam, L ;
Tchou, P ;
Lesh, M .
CIRCULATION, 2000, 102 (16) :1879-1882