External Quality Assessment in The Netherlands: time to introduce commutable survey specimens. Lessons from the Dutch "Calibration 2000" project

被引:29
作者
Baadenhuijsen, H
Kuypers, A
Weykamp, C
Cobbaert, C
Jansen, R
机构
[1] Univ Nijmegen Hosp, Dutch Fdn Qual Assessment Clin Labs, NL-6500 HB Nijmegen, Netherlands
[2] Queen Beatrix Hosp, Winterswijk, Netherlands
[3] Amphia Hosp, Breda, Netherlands
[4] St Anna Hosp, Geldrop, Netherlands
关键词
calibration; commutability; enzyme activity; External Quality Assessment; reference materials;
D O I
10.1515/CCLM.2005.052
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The performance of suitable secondary reference material for the use of trueness control of six routinely measured clinical enzymes in the Dutch External Quality Assessment (EQA) scheme is described. The reference material of choice was selected using the split-patient-sample between-field method (twin study) design as described in an earlier study of the Calibration 2000 project in The Netherlands. This material, which was proven to be commutable for all wet chemistry systems, was implemented as the national enzyme calibrator. It consisted of a cryo-protected lyophilised serum with-additions of recombinant human enzymes. Various batches of the frozen version of this material without cryo-protection additive, called native EQA samples, were used in the general EQA scheme for performance evaluation. The results of Calibration 2000 calibrated and non-Calibration 2000 calibrated laboratories were compared for both the regular (spiked with non-human enzymes) and native EQA samples in terms of precision and bias with established reference method values for the native samples. The regular samples showed mean between-laboratory CV ranges for all six enzymes involved (low-high) of 5.5-10.3% for the non-calibrated users vs. 4.6-10.8% for the calibrated users. For the native samples these respective ranges were 5.2-9.9% vs. 2.2-4.9%. Without exception, the group of Calibration 2000 calibrated users showed the lowest bias against the reference method values. Regular EQA samples (spiked with non-human enzymes) showed poorer performance than native samples and are not suitable for accuracy assessment purposes, the main aim of EQA schemes. Native samples that are commutable should be used for trueness control in current EQA schemes.
引用
收藏
页码:304 / 307
页数:4
相关论文
共 24 条
[1]  
AOKI R, 1996, P 16 INT C CLIN CHEM, P50
[2]  
BAADENHUIJSEN H, 1995, CLIN CHEM, V41, P724
[3]  
BAADENHUIJSEN H, 2002, CLIN CHEM, V48, P1521
[4]  
BAIS R, 1994, EUR J CLIN CHEM CLIN, V32, P639
[5]  
BERGMEYER HU, 1986, J CLIN CHEM CLIN BIO, V24, P497
[6]  
BERGMEYER HU, 1986, J CLIN CHEM CLIN BIO, V24, P481
[7]   Impact of reference materials on accuracy in clinical chemistry [J].
Franzini, C ;
Ceriotti, F .
CLINICAL BIOCHEMISTRY, 1998, 31 (06) :449-457
[8]  
GRANNIS GF, 1979, AM J CLIN PATHOL, V72, P285
[9]   RECOMMENDED METHOD FOR THE DETERMINATION OF CREATINE-KINASE IN BLOOD MODIFIED BY THE INCLUSION OF EDTA - COMMITTEE ON ENZYMES OF THE SCANDINAVIAN SOCIETY FOR CLINICAL-CHEMISTRY AND CLINICAL PHYSIOLOGY (SCE) [J].
HORDER, M ;
MAGID, E ;
PITKANEN, E ;
HARKONEN, M ;
STROMME, JH ;
THEODORSEN, L ;
GERHARDT, W ;
WALDENSTROM, J .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1979, 39 (01) :1-5
[10]  
HORDER M, 1991, EUR J CLIN CHEM CLIN, V29, P435