Improvements of hydride generation for the speciation of arsenic in natural freshwater samples by HPLC-HG-AFS

被引:48
作者
Bohari, Y
Astruc, A
Astruc, M
Cloud, J
机构
[1] Univ Pau & Pays Adour, LCABIE, CNRS, UMR 5034, F-64000 Pau, France
[2] Mulawarman Univ, Dept Chem, Samarinda, Indonesia
[3] Soc Spectrafrance SA, F-64053 Pau 9, France
关键词
D O I
10.1039/b101591p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new gas-liquid separator was used to improve the hydride generation step of a hyphenated HPLC-HG-AFS system applied to arsenic speciation studies. Optimisation of the hydride generation atomic fluorescence detection with this new device produced by SpectraFrance led to a significant improvement in performance. Absolute detection limits were as low as 5-7 pg As for the four arsenic species usually encountered in water samples: As(III), As(V), monomethylarsonic acid (MMAA) and dimethylarsinic acid (DMAA). Using a 100 mul injection volume the concentration detection limits were in the range 0.05-0.07 ng ml(-1). The optimised procedure was applied to determine arsenic speciation in a wide range of natural fresh water samples.
引用
收藏
页码:774 / 778
页数:5
相关论文
共 27 条
[1]  
AMRAN B, 1995, QUALITY ASSURANCE EN, P285
[2]  
BOHARI Y, 2001, THESIS U PAU FRANCE
[3]   Determination of arsenic species in seawater by flow injection hydride generation in situ collection followed by graphite furnace atomic absorption spectrometry - Stability of As(III) [J].
Cabon, JY ;
Cabon, N .
ANALYTICA CHIMICA ACTA, 2000, 418 (01) :19-31
[4]   DEVELOPMENT OF AN ATOMIC FLUORESCENCE SPECTROMETER FOR THE HYDRIDE-FORMING ELEMENTS [J].
CORNS, WT ;
STOCKWELL, PB ;
EBDON, L ;
HILL, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :71-77
[5]   Determination of arsenic, antimony, selenium, tellurium and bismuth in nickel metal by hydride generation atomic fluorescence spectrometry [J].
Feng, XJ ;
Fu, B .
ANALYTICA CHIMICA ACTA, 1998, 371 (01) :109-113
[6]  
Gomez-Ariza JL, 1998, APPL ORGANOMET CHEM, V12, P439, DOI 10.1002/(SICI)1099-0739(199806)12:6<439::AID-AOC718>3.0.CO
[7]  
2-8
[8]   A comparison between ICP-MS and AFS detection for arsenic speciation in environmental samples [J].
Gómez-Ariza, JL ;
Sánchez-Rodas, D ;
Giráldez, I ;
Morales, E .
TALANTA, 2000, 51 (02) :257-268
[9]   Speciation of arsenic and selenium compounds by HPLC hyphenated to specific detectors: a review of the main separation techniques [J].
Guerin, T ;
Astruc, A ;
Astruc, M .
TALANTA, 1999, 50 (01) :1-24
[10]   Optimization of hydride generation atomic fluorescence spectrometry for the determination of trace amounts of germanium: emphasis on acidity and interferences [J].
Guo, XM ;
Guo, XW .
ANALYTICA CHIMICA ACTA, 1998, 373 (2-3) :303-310